Item 3.1 - Bury Main Office:
3601 Thurston Avenue, Anoka, MN 55303
Phone: 763/427-5860 Fax: 763/427-0520
www.haa-inc.com
MEMORANDUM
TO: Honorable Mayor and City Council
CC: Adam Flaherty, City Administrator/Finance Director
Audra Etzel, City Clerk
Dan Licht, City Planner
Dave Kendall, City Attorney
Ronald J. Wagner, City Engineer
Tom Bury, Bury Manufacturing, LLC
Erik Hedman, Anderson Engineering
FROM: Brent Larson
DATE: May 12, 2021
RE: Bury Industrial; Outdoor Storage IUP Amendment- Submittal Review
We have reviewed the following information provided by Anderson Engineering of Minnesota, on
behalf of Bury Companies, Inc. regarding the Outdoor Storage IUP Amendment for Bury industrial
subdivision.
Site, Grading and Landscape Plans, dated 4/15/2021 by Anderson Engineering
The submittal is to be considered for preliminary and final acceptance. We would offer the following
comments:
Site and Grading Plan
1. Plans shall be signed by a registered Minnesota engineer.
2. The grading of the proposed storage area is in general agreement with the original approved
graving plans for the Bury Industrial Park.
3. The proposed new driveway and storage lot is to be gravel. Drainage arrows with grades shall
be provided to help with drainage review. Any grades less than 1% are discouraged. The site
general has sheep flow/drainage and no concentrated flow discharging from the gravel area
therefore concern for the gravel material leaving the site is minimal.
4. The driveway entrance connecting to 73rd Street shall be paved up to the right-of-way. The
proposed concrete valley gutter does not appear to be necessary and shall be eliminated as all
the water is being directed toward the storage area parking lot. There will be a concentrated
storm water runoff at the south ends of the curb to the parking lot which will like cause sever
erosion. Some method to deliver this storm water to the ditch without erosion will be
necessary (catch basins at the end of the curb and directed into the culvert would be the
preferred method).
May 12, 2021
Page 2
5. The driveway culvert size shall be 15” minimum diameter.
6. The storm pond NWL (965.0), 2-yr(966.12), 10-yr(966.91), and 100-yr(968.0) high water
elevations shall be labeled. The all three storm events will cause standing water the ditch
along 73rd Street for a time.
Landscaping
7. Subject to City Planners review.
Summary and/or Recommendation
We recommend approval contingent upon the above comments being addressed.