Loading...
07-07-08 PCITEM 3--, NORTHWEST ASSOCIATED CONSULTANTS, INC. 4800 Olson Memorial Highway, Suite 2,02, Golden Valley, MN 55422 Telephone: 763.231.2555 Facsimile: 763.231.2561 planners@nacplanning.coni PLANNING REPORT TO: Otsego Planning Commission FROM: Daniel Licht, AICP RE: Otsego — Cummings Mobility, Inc. REPORT DATE: 30 June 2008 APPLICATIO DATE: 5 June 2008 NAC FILE: 176.02 CITY FILE: 2008-23 BACKGROUND Hagen Builders has submitted plans for construction of a 20,800 square foot manufacturing building for Cummings Mobility, Inc. Cummings Mobility, Inc., currently located in Hanover, Minnesota, converts passenger minivans into disability accessible vehicles. Vehicles will be converted, offered for sale and serviced on the site, as well as distributed to other automobile dealers. The subject site is Outlot A, Otsego Industrial Park 5th Addition, which was approved in 2002 along with extension of Jansen Avenue. The parcel abuts 1-94 and is west of the existing Otsego Industrial Park lots developed with mini -storage and the Apex Building Center along Jansen Avenue. The submitted application includes consideration of a final plat, IUP to allow accessory outdoor sales and site/building plan review. Exhibits: A. Site location B. Site Plan C. Building Elevations D. Building Floor Plans E. Grading Plan F. Utility Plan ANALYSIS Zoning. The subject site is zoned 1-2, General Industrial District. The conversion of passenger vehicles for disability accessibility and vehicle service is an allowed manufacturing use within the 1-2 District. The principal building also includes 3,900 square foot floor area for vehicle service and display, which is an allowed accessory use within the 1-2 District provided that the area does not exceed 30 percent of the area of the principal building. The proposed sales area is 24 percent of the area of the principal building and complies with Section 20-86-6.A of the Zoning Ordinance. An island area to the east of the principal building is also proposed for outdoor vehicle sales display, which is an interim use in the 1-2 District subject to the criteria established by Section 20-86-4.0 of the Zoning Ordinance. Consideration of the interim use permit application is to be based upon, but not limited to, the following criteria: The proposed action's consistency with the specific policies and provisions of the Otsego Comprehensive Plan. Comment: The Comprehensive Plan guides the subject site for industrial uses to encourage job growth and expansion of the City's tax base taking advantage of visibility and access to the 1-94 corridor. The proposed use is consistent with these objectives and ideally suited to the subject site. 2. The proposed use's compatibility with present and future land uses of the area. Comment: The subject site is surrounded by the following existing/planned land uses. The proposed business will be compatible with the surrounding area. Direction Land Use Plan Zoning Ma Existing Use North Industrial 1-2 District 1-94 MNRoad 1-94 West Ind. Park East Industrial 1-2 District Mini -Storage South Industrial 1-2 District Undeveloped West Office Park A-1 District Agriculture 3. The proposed use's conformity with all performance standards contained within the Zoning Ordinance and other provisions of the City Code. Comment: The proposed use is required to conform to all applicable standards of the Zoning Ordinance, Subdivision Ordinance and Engineering Manual. 4. Traffic generation of the proposed use in relation to capabilities of streets serving the property. Comment: The subject site will be served by an improved industrial street connecting to a regional minor arterial street. Traffic generated by the proposed use will be within the capacities of these roadways. 5. The proposed use can be accommodated by existing public services and facilities and will not overburden the City's service capacity. Comment: The proposed use is within a planned industrial area and can be accommodated by existing City services. Shoreland Overlay District. Western portions of the subject site are within the shoreland overlay district of a Natural Environment Lake. Although it appears that the site improvements are outside of the Shoreland Overlay District, the site plan must be revised to illustrate the boundary to verify this, subject to review and approval by City staff. Building Design. The proposed building has a 16,000 square foot print and 20,800 gross square foot area with second story office space above the sales area at the northeast corner. The primary entrance of the building faces north towards 1-94 and is set forward of the main part of the building for emphasis. The exterior materials include stucco on all four sides with cultured stone accents on the north, east and west sides. The proposed materials comply with Section 20-17-4.6 of the Zoning Ordinance for required materials within the 1-2 District. The building is 24 feet tall to the top of the eves, which is within the 35 foot height allowed in the 1-2 District. Landscaping Plan. No landscape plan has been submitted. Section 20-16-7.0 of the Zoning Ordinance requires submission of a landscape plan for the subject site with emphasis on the perimeter of the site, base of the building and perimeter of parking/loading areas. Landscape areas are to be provided with in ground irrigation for maintenance. The landscape plan is to be subject to review and approval of City staff. Access. The subject site will be accessed via an extension of Jansen Avenue with one driveway to the public street. Right-of-way for the extension of Jansen Avenue was platted with the Otsego Industrial Park 5th Addition. The development contract executed at the time included approved plans for the construction of the roadway consistent with the City's standard specifications for a 10 -ton industrial street, but no securities as the timing of the project was not known. The applicant will be required to post securities for the construction of Jansen Avenue, including removal of the temporary cul-de-sac at the current terminus of the street. Lot Requirements. The following table outlines lot requirements applicable to the subject site. The proposed development complies with the lot requirements of the 1-2 District. Minimum Lot Area Min. Lot Width Max. Bldg. Cover Setbacks Jansen Ave. Side 1-94 Required 2.Oac. 200ft. 50% 30ft. 20ft. 30ft. Proposed 7.Oac. 690ft. 5% 260ft. 140ft./290ft. 100ft. Outdoor Sales. There is a 3,600 square foot island to the east of the principal building intended for outdoor display of vehicles manufactured on the subject site. Outdoor sales and display as an accessory use is allowed as an interim use with the 1-2 District provided that the area is on a hard surface and is not larger than 50 percent of the area of the principal building. The sales area will be on a hard surface and the area of the outdoor display is 17 percent of the area of the principal building. Off -Street Parking. The table outlines the calculation of required parking in accordance with Section 20-21-9 of the Zoning Ordinance: Use Area Requirement Stalls Office 4,800sf. 1 stall/ 200sf. 24 Indoor Sales 3,900sf. 1 stall / 500sf. 8 Outdoor Sales 3,600sf. 1 stall / 3,000sf. 2 Manufacturing / Service 1 stall / 350sf. 35 TOTAL 69 The site plan provides 47 parking stalls, whereas 69 are required by the Zoning Ordinance. We recommend that an additional 22 parking stalls be shown on the site plan as proof -of -parking stalls and that the development contract includes provisions allowing the City to require construction of the stalls if a need is determined to exist. A condition of the IUP and proof -of -parking agreement is to be that all vehicles and equipment must be parked on a paved surface. All of the proposed parking stalls conform to the dimensions required by Section 20-21- 4.A of the Zoning Ordinance. The driveways and parking areas are to be paved with asphalt and surrounded by perimeter concrete curb. The curb along the south edge of the pavement to the south of the principal building is a valley curb to allow for possible expansion of the site and or addition of other principal uses in the future. Signs. The subject site is within the Freeway Sign District established along 1-94. The total area of all signs may not exceed 15 percent of the wall area facing a public street. One freestanding sign not to exceed 200 square feet and a height of 50 feet is allowed, setback 15 feet from all property lines. Individual wall signs may not exceed 200 square feet. The submitted site plan identifies a freestanding sign near the site entrance to Jansen Avenue at a location compliant with the required setback. All signs require issuance of a sign permit prior to installation on the subject site/building. Trash. The site and building plans do not identify interior or exterior trash storage areas. Section 20-16-15.13 of the Zoning Ordinance requires that any trash container stored outdoors must be within an enclosure constructed of materials consistent with those used for the principal building. An exterior trash enclosure must be of sufficient area and height such that no automobile related parts or other refuse is visible. Trash storage shall be subject to review and approval by City staff. Lighting. No lighting plan has been submitted. A photometric light plan showing the type, location, height and illumination pattern of all sight lighting must be submitted. The lighting plan must conform to Section 20-16-10 of the Zoning Ordinance and is subject to review and approval by City staff. Grading Plan. The applicant has submitted a grading plan for the subject site. All stormwater runoff is to flow to a regional stormwater basin at the west edge of the subject site established with the approval of the Otsego Industrial Park 5th Addition. The proposed grading plan is subject to review and approval by the City Engineer. Utility Plan. Utilities will be provided by on-site septic and well system. The applicant has provided a utility plan showing the location of the on-site utilities, including primary and secondary drainfields. The utility plan also shows primary and secondary drainfield sites for potential additional users on the subject site. The utility plan is subject to review and approval of the City Engineer. Easements. Drainage and utility easements were established at the perimeter of Outlot A as required by Section 21-7-15 of the Subdivision Ordinance and over the regional stormwater basin with the approval of the Otsego Industrial Park 5th Addition final plat. The need for additional easements shall be subject to review and approval by the City Engineer. Park Dedication. Park dedication for the Otsego Industrial Park 5th Addition was deferred until development of the outlots. Payment of a cash fee of $3,500.00 per gross acre for Outlot A and the right-of-way for Jansen Avenue must be made with the development contract. The estimated park and trail dedication fee in lieu of land is shown below: Lot 1/Block 1 + Jansen Avenue x $3,500.00 = park fee in lieu of land 7.Oac. + 1.3ac. x $3,500.00 = $29,050.00 Final Plat. The applicant must submit a final plat in the form required by Section 21-6-3 of the Subdivision Ordinance for recording to establish Outlot A as a buildable lot/block. The final plat document shall be subject to City staff review and approval prior to being signed by the Mayor and City Clerk. Development Contract. The applicant is required to enter into an amended development contract with the City regarding construction of Jansen Avenue. The development contract shall provide for securities for construction of the public street and payment of park and trail dedication fees in lieu of land in addition to the items covered by the existing development contract for Otsego Industrial Park 5th Addition. The development contract shall be subject to review and approval by the City Attorney. RECOMMENDATION Our office recommends approval of the applications regarding Cummings Mobility, Inc. as set forth below. 5 POSSIBLE ACTIONS A. Motion to approve an IUP for accessory outdoor sales, site and building plans and final plat for Cummings Mobility, Inc., subject to the following conditions: 1. The interim use permit shall terminate on the happening of any of the following events, whichever first occurs: a. Upon violation of conditions under which the permit was issued. b. Upon change in the City's zoning regulations that renders the use non -conforming. C. A change in occupancy or redevelopment of the use or property upon which it is located. 2. The site plan shall be revised to illustrate the boundary of the Shoreland Overlay District. 3. A landscape plan as required by Section 20-16-7.0 of the Zoning Ordinance shall be submitted and is subject to review and approval by City staff. 4. The outdoor sales and display area is limited to vehicles modified/converted on the subject site. 5. All vehicles and equipment shall be parked on an asphalt or concrete surface. 6. The site plan shall be revised to illustrate 22 proof -of -parking stalls with provisions incorporated as part of the development agreement allowing the City to require construction of said stalls if the City Council finds a need exists. 7. All signs shall comply with Chapter 37 of the Zoning Ordinance and require issuance of a sign permit prior to installation on the subject site/building. 8. Outdoor storage of any trash containers be within an enclosure as required by Section 20-16-15.13 of the Zoning Ordinance, subject to review and approval by City staff. 9. A photometric light plan showing the type, location, height and illumination pattern of all sight lighting shall be submitted and is subject to review and approval by City staff for compliance with Section 20-16-10 of the Zoning Ordinance. Is 10. All grading, drainage and erosion control issues shall be subject to review and approval by the City Engineer. 11. All utility plans shall be subject to review and approval of the City Engineer. 12. All easements shall be subject to review and approval by the City Engineer. 13. The applicant shall pay at the time the development contract is executed. a cash fee of $3,500 per gross acre for the area of Outlot A and Jansen Avenue right-of-way to satisfy park and trail dedication requirements. 14. The applicant shall submit a final plat in the form required by Section 21-6- 3 of the Subdivision Ordinance, which is to be subject to City staff review and approval prior to being signed by the Mayor and City Clerk. 15. The applicant shall enter into an addendum to the Development Contract for Otsego Industrial Park 5th Addition, subject to review and approval by the City Attorney. B. Motion to deny the application based on a finding that the requests are inconsistent with the Comprehensive Plan, Zoning Ordinance and Subdivision Ordinance. C. Motion to table. C. Mike Robertson, City Administrator Judy Hudson, City Clerk/Zoning Administrator Andy MacArthur, City Attorney Ron Wagner, City Engineer Doug Cummings, Cummings Mobility, Inc. Michael Hagen, Hagen Builders, Inc. 7 II CI lki ;(eff VICINITY MAP CUMMINGS MOBILITY INC. OTSEGO,MINNESOTA PROJECT SITE_Q In LOCATION MAP PRELIMINARY CONSTRUCTION PLANS CONSTRUCTION NOTES: ALL E%I LOO ,1:eR1RE5 SUCH AS BWNOARr. BUR➢MION tt LOCATOHi METUNOi CONTOURi t EU:VARIXIS MERE P0.0NOE0 By OMNFA. 2 CONTRACTOR SHALL NOT START UR 1 CONSRiUCRON ENRO EEmP STRUCNRE S OP ORAMING RENEW BV 1 NO BY ENpNEER. BE - INTHOUT WUTIFH FOR SITE, GRADING and UTILITIES JUNE, 2008 Owner: CUMMINGS MOBILITY INC. 11238 RIVER ROAD NE HANOVER, MN 55341 (763) 498.7887 Engineer: WHEILLY ENGINEERING & ASSOC. INC. 250 ELM ST E ANNANDALE, MN 55302 (320) 490.4221 SHEET INDEX 2. SITE PLAN 3.GRADING PLAN 4. SWPP PLAN S. SWPP DETAILS 6. UTILITY PLAN Surveyor: TAYLOR LAND SURVEYORS, INC. 213 W BROADWAY P.O. BOX 179 MONTICELLO, MN 55362 (763) 2953388 xsey ve �7x MW —z— (oycl SNVId NollonU1SNOO ANVNIWI13Ud IZZ -061 WO sued �Ae m7o710 M:99 NN alepuouuy NVId 311S g u7 cZll xog '0'd d r a �n;M loan m�m"wsma. roi ae rwr0o '3 '1S N13 OSL SIO 'oul •oos77V V 6ulJOaul6u3 A1119H.4 '.UNIW '0!73 ONIAlI118l180WS9NiWWf10 N P P; 4z X11 yy �, � EFEP€�iQEifiFEQ�i �B I t pf I �Sh I a / ;7''P N. It i is Al I E � 1� �' o V / i .•�. QQ I i 1 / I 1 _ � I tlbtl RR . I 1 ♦ // / / �/ � Bs 7 SSI I 1 li / ✓�A (111 4zo i M a oe�oi I 4 vette=_ aa Y 8 Z 1 � 1 ♦ 1 \ I \ fb43 � e I •'� / � Qba � o z @ 8 e � 9zra Onman :arra :.e aakOaw ysyyyiy 00LL((I „re LLr-okr ((Lo5 wwe ZOCSS NW alupuu--V rT CZII xOG '0'd ,7hJ '3 1S W13 OSZo 'OUI 'OOtitr )p 6YIINUI6U3 A11191-1,0dlOS3NNIW'0!)3S10 SNVId NOLL00tl1SN00 ANVNIWI13Ud NVId DNIGVUD 'ONIA111180W SONIWWf10 - 10 0 =M ,O '"iimk 1O `yn�i0 '°` ..�.w m aro �aakOsaO swan arvO 1 / N r Ail l4 ,., i_a✓JN I' 'I �1 I 1 1 I I 44 8 i F I 41 9$' + ,Yi I L'1 5 pl yy y■ a ! 1d O Ns � 1 yyyMd I I 1 'IX s I rq\\ \ it s j l � . m+.. BURLINGTON NORTHERN RAILROAD ----------- _ - T v°KE _ mP) � GRAPHIC SCALE .__..•�'"_ ter°° ._ �oo.00 ______ _ .. _.___ __• • �*N Es1D�W __. RDO. _.__..._ mnsmucma. \ / •' `) // / °wwMINGs 1`D \ / Y• J\ � � g Op°pOSED 0U 1. INO NII4 BlS`�0 �iG ,s n rte. 1'J.F�s � = vP°It/ ` dJ' Ny'sezro �E'. \/ \\ j►s �L'" e W. unm° ..D. m cws>A'��no.,.n. m w.cmx .N,n, �� \`,. a Eea °'naP1 uD �.ww.aw D. 4 wx ].00 LT, De,rEoiDn (a,owry \\ 1 1 $ % smw .,m..ao wsmxm.. . �a»a °uwmx wo n 1 w1Ewx. �______ "ofofT 7 .�D a „N .. v, ci Z � a .»< am .�. a....c o suss .omn omcn.x. tsa uxoswc Pu.l J_ w Z U .1 it _a«D� »..DcwnDN a,u ,,.E p z a if a i a o Easm�EmN,. swm m.owwui ,»< C7 W N Y VMnmN oP casmVC�Dx. Z F O _ mVaMr snwwwmM Mf6 Y dols➢ B. M Fwom. Cc Z G .ms AK OMIINno4etrDCen assn a GOPHesLL NE omxe. ER STATE OCALL P-CT 10 Pw- 4 nOF 6 auras bxvvnn .o¢ �Imin v�vrr�i�rn1s o.a amrmue x mt1AA{fllW'MMIJ110Y� call IAaI „ =<,momaa w axaaAa ama iw r :,t tea. wmu�a wanmz.mz,.z�v+vi3oaa.xv.lsova vmloen.�m�mam.ar. MOUDaLOOd law 'IIYIOIAI All dIN s � 111Y 1l Illa a1AAVY A01 Arl OM A lNN Lal 01 O SA w1Y l�NI111 >fIOII�IMyIIA�.W sw .w+a smwm. m vnwm m sw ,n �JNISSVd 3afI3A3B 1N3�Ef3d lbLLtlOVtl'J b �a wumm va'stmv mora .I i s8 r 88 I� ✓,. / 1 I I cewx nv n3tl :nro Ae 031°31tl •au I 90LZ-KL (oLf) me .Cit -061 (OC�f) rwoW M99 Nry IoP�o�w CLU vog 'p'd '3 '1S V113 C, •nose Bu luau Bu A 0 V )P I I 3 IU H,a SNVId NOiionuis NOB AUVNIWI13Ud NVId A.Lnu l VLOS3NNIW `003510 -ON1 A1111GOW SONIWWf10 - iO _ D ,,,,,o „6 >t1 rvv.w n vru lon m\ +e rw.ruo O10 :03 1530 :6tg61n3tl LYO .o •,111 , � Z / .. '\, '► IIIUiI' N J 1 .s31 p�3 � 1 U �x y 5 !9 9 I \\ 6 1 I ' b 1{ 1 / L t1 I � y• p ( I se U iso c' I I 1 1 2V .I i s8 r 88 I� ✓,. / 1 I I Z .o •,111 , � Z 1S .. '\, '► N J 1 .s31 p�3 � 1 y ' b 1{ 1 / L �dF2���ii 9 ►� / / 1 / Hakanson �0 Anderson 1 nder3601 Thurston Avenue, Anoka, MN 55303 AInc. Phone: 763/427-5860 Fax: 763/427-0520 MEMORANDUM To: Honorable Mayor and City Council cc: Mike Robertson, Administrator Judy Hudson, Clerk Dan Licht, NAC Andy MacArthur, City Attorney Ronald Wagner, P.E. City Engineer Cummings Mobility Inc. D'Heilly Engineering & Associates, Inc. Taylor Land Surveyors, Inc. From: Brent Larson, P.E. Date: July 2, 2008 Re: Cummings Mobility (Outlot A of Otsego Industrial Park 5th Addition) We have reviewed the Preliminary Construction Plans, printed 6/24/08, for the above -referenced project and would offer the following comments: Otsego Industrial Park 5th Addition 1. The Final Plat for Otsego Industrial Park 5t" Addition has been filed with Wright County. 2. Construction and Grading Plans, revision 1/10/03, were approved but the site has not been constructed at this time. 3. Because the 5h Addition has not been constructed at this point the wetland delineations and mitigation plans must be resubmitted for approval. The resubmitted wetland delineation and mitigation reports have been received and are under review. Preliminary/Final Plat 1. Cummings Mobility is proposing to develop Outlot A of the Final Plat for Otsego Industrial Park 5th Addition. No Preliminary or Final Plat for Cummings Mobility has been received at this time. Title Sheet 1. All sheets must be signed by a licensed professional Engineer. 2. Please include City Engineer in the signature line for Ronald J. Wagner, P.E. C:\Documents and Settings\TamiTocal Settings\Temporary Internet Files\Content.Outlook\09RYFWAZ\ot2500CummingsMobility rvwl.doc 3. We recommend adding an Existing Conditions sheet to the plans. The plans lack much of the required existing conditions required in a preliminary plan submittal. Please provide an additional sheet to include the following required items: i. Existing zoning classifications for land in and abutting the subdivision. ii. Total area of the proposed plat. iii. Show location, names, widths of existing streets, buildings, etc. iv. Identified by name and ownership, the adjoining unsubdivided or subdivided land. v. Provide the High Water Level (HWL) of all ponds and wetlands within or adjacent to the site. vi. Statement certifying the environmental condition of the site. 4. Location of boundary lines in relation to a known section, quarter section, or quarter -quarter section lines comprising a legal description of the property. 5. Provide contact names for the Owner, Engineer, and Surveyor. Site Plan & Traffic/Access Issues 1. Access to the site is being provided by making two new connections to existing Jansen Avenue NE. The western entrance appears to be a future access point and ends at the Right -of -Way (ROW). 2. Provide the datum for the benchmark. 3. The please provide widths for the driveway entrances to the site. 4. The primary and future septic systems encroach on the depicted easements along the east side of the property. The location of the septic systems or the easement must be revised. 5. The proposed storm sewer pipe throughout the site is missing. 6. Depict the proposed well location. Grading & SWPPP Plans 1. Please label the proposed grades along the curb and gutter and across the bituminous parking lot. We recommend a minimum 0.6% along curb and gutter and a minimum 1.0% over bituminous. 2. Depict the soil boring location(s) with the associated soil boring ID from the geotechnical report. (A geotechnical report was been submitted with Otsego Industrial Park 5th Addition. It is assumed that the same report is to be used for Cummings Mobility.) 3. Please label the 2 and 10 year HWL for the Northwest pond. 4. Please provide a legend. Hakanson Anderson CADocuments and SettingsUamiTocal SettingsUemporary Internet Assoc., Inc.. Files\Content.Outlook\09RYFWAZ\ot2500CummingsMobility rvwl.doc 5. Provide existing contours within 150' of the site. Some of the proposed contours do not agree with the along the property boundaries. (i.e. east of the site). 6. It is unclear if the grading south of Jansen Avenue NE is proposed or existing. 7. It appears that additional grading (swale) is needed along the east property line. It is unclear if the depicted contours in the primary septic system area are showing the proposed mound system (acceptable) or if the septic system is proposed in a fill area (unacceptable). Please verify. 9. The HWL of the pond will back up into the proposed swales near Apron 3, 7 and 10. This would cause the HWL to extend beyond the existing drainage easements. The 100 year HWL shall be covered by a drainage easement. 10. Depict and identify any existing wetlands or wetland mitigation areas within the site. SWPP Plan 1. We recommend that bale checks be placed downstream of storm sewer apron 3 and 7. 2. It is unclear where silt fence is to be placed. Currently it is shown around the septic areas only. Utility Plan 1. Please label the size, type, and inverts of the pipe and overflow structure in the northwest corner of the site. 2. Label the datum for the benchmark. 3. Provide flow arrows on the storm sewer. 4. Many of the storm sewer pipes have approximately 1.5' of cover in traffic areas. We recommend that a minimum 1.5' of cover in green areas and 2' of cover in traffic areas be provided. The parking lot has a typical section of approximately 2.17' therefore any pipe with less cover than 2.17' will be protruding into the parking lot base and possibly affects drainage in the select granular layer. 5. We recommend revising the storm sewer pipe grades to provide a minimum velocity of 3 feet per second (fps) throughout the storm sewer system. Stormwater Management 1. The stormwater is to discharge into the pond constructed with Otsego Industrial Park 5th Addition, along the west side of the property. This site is covered by the hydrology report submitted with the 5t' Addition. k Ha anson Anderson CADocuments and SettingsUamiTocal SettingsUempormy Internet Assoc., Inc. Files\Content.Outlook\09RYFWAZ\ot2500CummingsMobility rvwl.doc 2. The site provides sufficient freeboard and ponding depths. The site provides approximately 5' of freeboard between the Finished Floor Elevation and the Pond's HWL (100 year storm event). The site also has a maximum ponding depth of less than 1' within the parking lot and driveway. 3. Please provide storm sewer design calculations. Wetlands A wetland delineation report has been submitted and is under review. Environmental 1. A statement certifying the environmental condition of the site shall be submitted. (21-6-2.B.10.) Specifications 1. Please provide construction and grading specifications. Summary and/or Recommendations We recommend approval contingent on the above comments being addressed. CADocuments and Settings\TamiTocal Settings\Temporary Intemet Files\Content.Outlook\O9RYFWAZ\ot2500CummingsMobility rvwl.doc Hakanson 1 Anderson Assoc., Inc. ITEM 3_2 NORTHWEST ASSOCIATED CONSULTANTS, INC. 4800 Olson Memorial Highv�ay, Suite 202, Golden Valley, MN 55422 Telephone: 763.231.2555 Facsimile: 763.231.2561 plan nersanacplanning.com MEMORANDUM TO: Otsego Planning Commission FROM: Daniel Licht, AICP DATE: 25 June 2008 RE: Otsego — Zoning Ordinance; Accessory Buildings NAC FILE: 176.08 BACKGROUND A number of issues related to regulation of accessory buildings have been identified recently. The purpose of this memorandum is to outline these issues and suggest possible modifications to the Zoning Ordinance in response. Existing language proposed to be deleted is identified by a double strikethrough and language to be added is double underlined. ANALYSIS Rear Yards Abutting Collector/Arterial Streets. The Zoning Ordinance requires a 65 foot setback from collector or arterial streets defined by the Comprehensive Plan. New subdivisions occurring within the east and west sewer districts are designed such that the lots abutting collector or arterial streets are double frontage lots with the front of the house accessed from a local residential street. In this scenario, the yard abutting the collector or arterial street is functionally the rear yard of the property, but the same 65 foot setback applies (versus a 20 foot setback for interior lots). It is common that these double frontage lots abutting collector or arterial streets are designed such that the house is located at the 65 foot setback line. Section 20-16-4.13 of the Zoning Ordinance does not exempt accessory structures on these lots from the 65 foot setback. Within the developed sewered subdivisions, play sets, garden sheds and other structures have been erected within these rear yards that do not meet the 65 foot setback. In order to address these existing lots and ensure usable yard space for accessory structures, the following amendment is proposed: 20-16-4.B.3: a. Attached _accessory structures shall conform to principal building setbacks required for the zoning district in which the structure is located. b- Detached accessory structures may encroach into required side or rear yard setbacks when located in the rear yard of the lot, but shall not encroach into the required setback for a yard abutting a public street of a corner lot: 1. Detached accessory structures not exceedin one hundred fifty (150) square feet in gross floor area shall be setback at least five (5) feet from _side or rear -lot lines abuttingCher lots or ten (10) feet from a rear lot line abutting a_public right-of-way in the case of a double fronta Qe lot. 2. Detached accessory structures with a gross floor area Larger than one hundred fifty X50) square feet -shall be setback at least ten (10) feet from side or_rear lot lines abutting other lots or twenty (20) feet from a rear lot line abutting a public right-of- way in the case of a double frontage lot. C. No accessory structure shall be located within a required buffer yard, drainage and utility easement or Public right-of-way. Interior Lot Setbacks. A second setback issue related to detached accessory buildings larger than 1,000 square feet has been also been raised. Section 20-16-4.13.3 of the Zoning Ordinance currently requires that detached accessory structures larger than 1,000 square feet in all zoning districts conform to principal building setbacks. A similar provision is repeated for the R -C District in Section 20-60-8.C.2 to encourage clustering of buildings on a lot specifically within that district. Except within the A-1 and A-2 District on parcels larger than five acres, the maximum gross floor area of any single detached accessory building is 1,500 square feet. The principal building side and rear yard setbacks in districts other than the A-1 and A-2 District are 10 feet and 20 feet, respectively. The effect of this provision is to move the building 10 feet farther into the property from the rear lot line. Given that buildings larger than 1,000 feet are only allowed on lots larger than one acre within A-1, A-2, R -C, R-1, R-2, and R-3 District and the difference in building mass between 1,000 square feet and 1,500 square feet on parcels this size is negligible, City staff sees minimal benefit to requiring the principal building setback (except in the R -C District). As such, the proposed amendment outlined above would not require detached accessory buildings larger than 1,000 square feet to meet principal building setbacks. Sewer District Detached Accessory Building Area. The Zoning Ordinance was amended in 1998 to establish provisions for detached accessory buildings within the sewer service districts in anticipation of and prior to urban density development. Section 20-16-4.13.7 of the Zoning Ordinance limits the area of a detached accessory building to 150 square feet if there is an attached garage on the property and the total area of attached and detached accessory building area to 1,150 square feet. Allowance of additional area for detached accessory buildings may be an opportunity to reduce outdoor storage, which City staff has observed and dealt with as part of on-going code enforcement activities. Construction of a detached accessory building would also be more cost effective for existing properties than adding an additional garage stall to the principal building. The following language is offered for consideration to allow detached accessory buildings larger than 150 square feet only within the R -4A and R-4 District, which require minimum lot areas of 18,000 square feet and 12,000 square feet respectively. The provisions would allow for a detached accessory building in combination with the area of an attached garage based on lot area. The current standards for the R-5, R-6 and R-7 District, which require only a 9,000 square foot minimum lot area for single family uses, are not proposed to change. 20-16-4.B.7. Within the R-4ATand R-4- R � Zoning Districts: 3 re—jEee The combined gross floor area of attached and detached accessory buildings shall be as follows: Lot Area Maximum Total Floor Maximum Gross Floor (square feet) Area of all Attached and Area of a Detached Detached Accessory Accessory Structure Structures When an Attached (square feet) Garage Exists on the Same Lot (square feet) 0.00 to 15, 000 1,150 150 15,001 to 18,000 1, 220sf. 220 18, 001 or larger 1,300sf. 300 b. In no case shall the floor area of an individual detached accessory building exceed one thousand (1,000) square feet. bc. There shall be no more than one (1) detached accessory structure with a gross floor area larger than one ^hundred , y fifty (150), square feet per 9 B. Within the R-5, R-6 and R-7 Zoning Districts: a. No accessory detached building shall occupy more than one hundred fifty (150) square feet when accompanied by an attached gara ee on the same lot, nor shall the combined total floor area of accessory detached structures and/or an attached garage exceed one thousand two hundred (1,150) square feet. b. There shall be no more than one (1) detached accessory structure with a gross floor area larger than one hundred fifty (150) square feet per lot. CONCLUSION The Planning Commission will discuss this information at their meeting on 7 July 2008. City staff is seeking direction as whether the Planning Commission wishes to proceed with amendment of the Zoning Ordinance to address these issues and any modifications to the language as proposed. The Planning Commission may also schedule a public hearing to formally consider the amendment. C. Mike Robertson Judy Hudson Tim Rochel Ron Wagner Pat Hilden, 7094 Odell Avenue NE