ITEM 3.5 Resolution 15-59P OtkgoF MINNESOTA DEPARTMENT INFORMATION Request for City Council Action ORIGINATING DEPARTMENT: REQUESTOR: MEETING DATE: Public Works City Engineer Wagner October 12, 2015 PRESENTER(s): REVIEWED BY: ITEM #: City Engineer Wagner City Administrator Johnson 3.5 AGENDA ITEM DETAILS RECOMMENDATION: The Public Works Subcommittee and City Staff recommend approval of Resolution 15-59 Amending the Citv of Otsego EnRineerinlp, Manual. ARE YOU SEEKING APPROVAL OF A CONTRACT? IS A PUBLIC HEARING REQUIRED? No No BACKGROUND/JUSTIFICATION: The Otsego Engineering Manual has been revised in order to add, update, clarify, or remove various information to agree with the current City, State, or Regional standards, policies and or best management practices. The revisions have been discussed at the August 18th, 2015 Public Works Subcommittee meeting. All comments from this meeting have been addressed and incorporated in the attached summary. An outline of the changes is attached as Exhibit A and the Standard Plate Redlines. SUPPORTING DOCUMENTS: x ATTACHED ❑ NONE • 2015 Engineering Manual Update Summary • Revised Standard Plates (Redlines) • Resolution 2015-59 POSSIBLE MOTION Please word motion as you would like it to appear in the minutes. Motion to Approve Resolution 15-59 Amending the City of Otsego Engineering Manual. BUDGET INFORMATION FUNDING: BUDGETED: ❑ YES N/A o NO ACTION TAKFN ❑ APPROVED AS REQUESTED ❑ DENIED o TABLED ❑ OTHER (List changes) COMMENTS: EXHIBIT A 2015 ENGINEERING MANUAL UPDATE Summary of Revisions City of Otsego FORWARD Third paragraph revised to reference latest editions of the various referenced specifications and standards as well as added references to the the Minnesota Manual on Uniform Traffic Control Devices, Minnesota Pollution Control Agency Stormwater Manual and National Pollution Discharge Elimination System permit. ENGINEERING MANUAL I. Engineering Requirements 1. I.10, revised to more clearly define the procedure for completion and acceptance of required work in developments. , Added Initial City Acceptance requirements A-C. 2. 1.10 and IIL3.a, revised electronic "as -built" submittals to also accept Adobe (.pdf) files. 3. I.11, added the following; "I.11. All work shall be initially accepted as defined above before building permits will be issued. Before the final payment is made to the contractor by the developer, the City Engineer shall be satisfied that all work is satisfactorily completed in accordance with the approved plans and specifications." 4. I.12, added the requirement for shots a minimum of every 25' for grading lot grading certificates. I.13.a, revised to "developer shall guarantee all work ... for a period of one year from the date of Initial written Cily Acceptance of the work or project. The utilities will not be accepted prior to placement of the wearing course being constructed." 6. I.14, added the following; C:\Users\Tami\AppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outtook\L723WOXW\EXHIBIT A SUMMARY.doe 14. Final Cily Acceptance: No more than 30 day prior to the conclusion of the warranty period and before the improvements may be finally accepted by the City, the developer must schedule a walk-thru. The developer, his contractor, the City maintenance department, City utility department, and the City Engineer or his representative must be invited. Upon Final Acceptance by the City and conclusion of the warranty period, the City will assume responsibility for the public improvements. All inspection costs are the responsibility of the Developer II. Erosion Control Policy 7. II.2.1, added the following; 1. Infiltration basins shall be provided to treat the water quality volume as required by the NPDES permit. In area where infiltration is not possible as described in the NPDES permit Part III (typically Hydraulic "D" type soils or higher risk DWSMA areas), other volume reducing methods shall be provided to treat the water quality volume. If infiltration is not possible the reasoning shall be described in the SWPPP Narrative and all alternative volume reducing methods being used shall be described. 8. I1.3.a, revised to include a cost of $3,000/net to be held in the letter of credit for guarantee of compliance with erosion control measures and $250/lot or $1,000/net acre to be held in during the warranty period. M. City Standard Plans Some very minor changes have been made throughout this section, the following are the more notable changes; 9. III.1.p, added the following; p. All dead end streets serving more than 1 lot shall have a minimum 40' radii temporary cul-de-sac with 4" bituminous curb unless approved by the City Engineer. A temporary easement shall cover the temporary cul-de-sac beyond the platted right of way. (See Standard Plate 108A) 10. 1112.n, Add the last sentence "All rear yard draintile shall be solid PVC with cleanouts located at any bend and at the end of the line." 11. III.3 j All as -built plans shall include as -built pipe grades, invert elevations, rim elevations, and pipe lengths shown. All planned information shall be crossed out/struck-thru and the as -built information written next to it. C:\Users\Tami\AppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\L723WOXW\EXIIIBIT A SUMMARY.doe IV. City Standard Materials Some minor changes have been made throughout this section. Most changes are related to requiring HDPE "plastic" adjustment rings and the frames to be bolted to the top of the concrete structure on all sanitary sewer and forcemain structures as well as storm sewer manholes within paved areas. This requirement changed frame and casting necessary for these types of structures therefore the Neenah R-1642 frame and casting is required instead of the R-1733. Core -blue or 316 Stainless Steel nuts, bolts, and threaded rods are required for attaching these frames to the structures and all watermain fittings. The following some additional changes; 12. IV.2.c, revised to include concrete cable and Flexamat as options at storm sewer discharge points. 13. IV.2.h, added the following; h. The last 3 pipe joints at all RC flared end sections on storm sewer pipe and all RC Pipe culvert pipe joints shall be "tied" per MnDOT Standard Plate 14. IV.3.a, revised required sanitary sewer castings to Hamilton Kent Lifespan System, Neenah R-1642 or approved equal. The old frame and casting (R-1733) does not come with predrilled holes to anchor the frames to the top of the manhole. Also revised the waterproof frame and casting to include the Neenah R-1755-F2 (this was Otsego's previously approved waterproof casting ). 15. IV.3.d & IV.3.e added the following; d. All frames for sanitary and forcemain manholes shall be sealed with manufacture recommended adhesive to the top of the concrete structure or adjustment ring(s) and bolted directly to the top of the concrete structure using 316 stainless steel nuts, bolts and/or threaded rods. e. Final grade adjustments may be made by adding rings and raising the frame or with metal casting inserts per the manufactures' requirements. 16. IV.4.h., Change Manhole Sealing section to the following; h. Manhole Sealing All existing and proposed sanitary sewer manholes shall be watertight and receive a watertight frame and casting system. All forcemain manholes and all gravity sanitary sewer manholes within green spaces or within the 100 yr HWL area shall receive a waterproof frame and casting system. All chimney areas (i.e. adjustment rings) shall be externally sealed if locking "plastic" adjustment rings are used or internally sealed where concrete C:\Users\Tami\AppData\Local\Microsoft\Windows\Temporary Intemet Files\Content.Outlook\L723WOXW\EXHI13IT A_SUMMARY.doc adjustment rings are used. All joints 3' above the water table and below shall be sealed. All seals shall be installed per the manufactures specifications. i. Standard Frame and Casting System 1. The standard watertight frame and casting system shall consist of Neenah R-1642 system with cast iron frame, solid cast iron lid, cast iron extension ring, HDPE "plastic" adjustment rings, and external chimney seal or; 2. Hamilton Kent, Life Span system with an elastomeric frame, elastomeric extension ring, elastomeric adjustment risers, and cast iron locking lid. Lid shall have (3) locking cam lugs, or approved equal. ii. Waterproof Frame and Casting System The waterproof frame and casting system shall consist of Neenah R-1755- F2 system with cast iron frame, solid cast iron lid, & inner lid. Though not typical if necessary HDPE "plastic" adjustment rings shall be used with external chimney seals. The insert extension rings are not allowed for final casting adjustments with these frames and castings or; 2. Hamilton Kent, Life Span system with an elastomeric frame, elastomeric extension ring, elastomeric adjustment risers, and cast iron locking lid. Lid shall have (3) locking cam lugs, or approved equal. 17. IV.4.h.ii, changed Sanitary Sewer Manhole Chimney Seal to allow external seals as the manufactures of the HDPE plastic rings recommend the external chimney seals when installing the HDPE rings. Added the following IV.4.h.ii.I External chimney seal shall consist of an external EPDM flexible rubber sleeve and a non -hardening butyl mastic adhesive. (Manufacturer: Sealing Systems, Inc., External Infi-Shield Gator Wrap) 18. . IV.5.d, revised to ".... A stainless steel spring mounted frilly wrapped fiberglass locator rod shall be attached to each hydrant...." 19. IV.5.j, added the following IV.5 j All nuts, bolts, and rodding shall be high -strength, low -alloy steel and shall be coated with a ceramic -filled, baked on fluorocarbon resin (i.e. Cor- Blue Bolts) or shall be ASTM F 593 316 Stainless Steel in compliance with ANSI/AWWA C111/A21.11. Anti -seize bolt/nut coating or spray/paste compound shall be used on all stainless steel bolting operations. 20. IV.51, added Irrigation Service section as follows; C:\Users\Tami\AppData\Local\Microsoft\Windows\Temporary Intemet Filcs\Content.Outlook\L723WOXW YHIBIT A SUMMARY.doc IV.5.k. Irrigation Services i. When irrigation line is connected to a 12" watermain or greater install a 4" tee and 4" gate valve to help isolate the irrigation line from the main. A 4" cap with a 2" corporation shall be installed for the irrigation service. ii. All irrigation lines connecting to a 10" watermain or less shall be 2" or less and wet tapped. These lines shall meet all the requirements above for services a curb stop for shutoff isolation purposes. iii. Irritgation service shall be equipped with a V4 turn ball valve, metering equipment, and backflow preventer, Water meter shall be obtained at City Hall with payment of established fee, and installed in accordance with directions. iv. Above ground equipment shall be completely enclosed by a metal or other approved structure and shall be level and mounted a concrete pad. v. All irrigation services shall have a rain or moisture sensor if connected to City water. V. Testing Requirements 1. V.2.d, added the following; a. Test Rolling: Roadway subgrades shall be test rolled prior to placing aggregate base. In areas where the roadway subgrade consists of a "clean" sandy material a test roll may be waived if approved by the City Engineer. If the test roll is waived on the subgrade it will be required on the aggregate base prior to paving. 2. V.4.a, revised to eliminate "1 test per 1000 tons of aggregate placed, 1 test daily when construction base." to agree with MnDOT's Schedule of Material Testing]. 3. V.5.b, revised to require "Modified Rice Denisites" 4. V.8.b.iv, added the following iv. The test shall be a minimum of 350 amps for 5 minutes 5. V.8.c, revised as follows; C:\Users\Tami\AppData\Local\Microsoft\Windows\Temporary Intemet Files\Content.0utlook\L723WQXW\EXHIBrr A_SUMMARY.doc i. Performed in the completed watermain after final flushing and before being placed in service. Two passing tests are required. One immediately after flushing and a second after a minimum of 24 hours later. ii. Test samples shall be taken from a minimum of 20% of the hydrants or per 2500 LF or watermain, whichever is greater. 6. Moved V.12 — Initial City Acceptance and V.13- Final City Acceptance to Engineering Requirements at front of manual. VI. Construction Requirements VI.1 and VIA revised to reference latest editions of references specifications. 2. VI.6, added Cold Weather Construction requirements as follows; VI.6 Cold Weather Construction a. Excavation (includes utility trenches) i. When excavating, frozen dirt chunks should be separated from non -frozen dirt. Frozen chunks shall not be placed back in utility trenches or within the street subgrade. ii. All excavations and utility trenches shall be backfilled each day to avoid creating more frozen chunks overnight and to provide sufficient cover over utilities in case a storm shuts down construction for an extended period of time. b. Sanitary Sewer, Watermain, and Storm Sewer: i. No frozen chunks in backfill. ii. All manholes and valves shall be adjusted to the current finished grade for access throughout the winter. iii. Concrete doghouses, inverts, and grout between adjustment rings (where allowed) shall have be not be allowed to freeze within the first 72 hours. If streets are not to be finished prior to winter shut- down, all concrete work except outside doghouses around pipes may be finished in the spring iv. Minimum cover shall be provided over all sanitary and water lines, including forcemain, hydrants, services and all stubs. If no traffic is allowed over the pipe 6' is sufficient for the winter otherwise in traffic areas a minimum of 7.5' is required. Special attention may C:\Users\Tami\AppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\L723WOXW\EXHI13IT A_SUMMARY.doe be needed to end of cul-de-sacs and where future streets are sub - cut and utilities are installed. v. All testing requirements shall be fulfilled prior to issuing building permits. c. Streets (including concrete curb and gutter) i. No frozen material shall be placed in the street subgrade or aggregate base. ii. New (unfrozen) material may be placed on a previous fully compacted layer frozen layer. iii. Curb and pavement cannot be placed on frozen ground. The temperature shall be 36' and rising at time of placement. Contractors may choose to place and compact extra material over the area and peel off the frozen material just prior to placing curb or paving. This frozen material shall not be used in the aggregate base. Subgrade/aggregate base still needs to be toleranced prior placing curb/pavement. iv. A cold weather plan for placing concrete in cold weather shall be submitted to engineer. Measures shall be taken to the concrete does not freeze within the first 72 hours of placement. A method to monitor maximum low temperatures in multiple places on the concrete under cold weather protection shall be addressed. If a section of curb is suspected of freezing, the concrete can be core drilled in place and tested. Any frozen concrete shall be removed and replaced. v. Concrete samples shall cure overnight in same conditions as concrete (i.e. under poly or under blankets, etc). vi. High early curb (adding calcium chloride) is allowed. vii. No vibratory actions near fresh concrete it reaches 3000 psi. viii. Pavement shall not be placed on frozen ground. ix. Wear Course paving is not allowed in the metro area after November 1st (MnDOT 2360.3.A.4) or when temperatures are below 32' (MnDOT 2360.3.D.2.c) d. Erosion Control C:\Users\Tami\AppData\Local\Microsoft\Windows\Temporary Intemet Files\Content.Outlook\L723WOxW\EXHIBIT A SUMMARY.doc Once ground is frozen seeding/mulching isn't as important as perimeter control and placing seed/mulch ASAP in spring. Dormant seeding on snow works is acceptable. Ultimately the contractor will be responsible for vegetation establishment and compliance with NPDES permit. ii. If silt fence is damaged and cannot be repaired due to frozen ground, bio-rolls or rock logs are an acceptable alternative. iii. Inlet protection (i.e. Wimco's) shall be removed from catch basins after the ground has frozen. They shall be reinstalled in the spring. VII. Storm Water Treatment Basins is now Storm Water Treatment 1. Revised entire section as follows (new in red); All stormwater facilities/treatment shall be designed to conform to the latest edition of the Minnesota Pollution Control Agency Stormwater Manual and National Pollution Discharge Elimination System permit, except as herein modified. 1. Storm water conveyance, storage and treatment systems shall be designed in accordance with the City of Otsego's policy on stormwater drainage as outlined in Appendix C. Typical basin construction and outlet structures are shown on the City Standard Plates in Appendix A. 2. Infiltration areas shall be designed in accordance with the latest edition of the Minnesota Pollution Control Agency's Stormwater Manual except as herein modified. IX. Shmaue, Striping and Lighting 1. Added "All traffic control devices and signing shall conform to the latest edition of the Minnesota Manual on Uniform Traffic Control Devices except as herein modified." APPENDIX A - STANDARD PLATES Revised the following Standard Plates 103 MSA Collector Urban Street Section —10 Ton 113 Industrial Collector Urban Street Section —10 Ton 203 Pacer Traffic Flange Hydrant 204 Hydrant & Hydrant Gate Valve Detail 205 Typical Resilient Wedge Valve & Box Installation —10" & under Watermain 206 Typical Butterfly Valve & Box Installation —12" & over Watermain 207 Seepage Pit Detail C:\Users\Tami\AppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\L723WOXW\EXRBrf A SUMMARY.doc 300 Sanitary Sewer Standard Manhole 305 Standard Drop Manhole 307 Waterproof Manhole Casting and Anchorage 308 Internal Chimney Seal 312 Forcemain Air/Vacuum Valve 313 Forcemain Cleanout 400 Slab -Top Manhole 401 Storm Sewer Standard Manhole 404 48" Diameter Shallow Depth Catch Basin 405 Standard Storm Manhole — Catch Basin 408 Standard Storm Manhole — Yard Inlet 409 27" Precast Catch Basin Yard Inlet 410 2" x 3' Catch Basin 411 Storm Manhole Adjustment Rings 500 Articulated Concrete Block at R.C.P. Outlet 706 Typical Drop Curb — Bike Trail 707 Typical Section — Bike Trail 805 Stop Sign and Street Name Sign Detail 806 Temporary Cut -de -sac Sign APPENDIX C - STORMWATER DRAINAGE POLICY 1. Revised to require all storm water modeling and storm sewer design to use NOAA ATALS 14 precipitation data. 2. Revised to reference MPCA NPDES infiltration requirements and state that infiltration designs shall be per the latest edition of the Minnesota Stormwater Manual. APPENDIX D - STREET CONSTRUCTION SPECIFICATIONS 1. Revised to the latest edition of the MnDOT Specification and traffic control manual (MNUTCD). 2. Revised required bituminous mixture to include the latest MnDOT approved "super -pave" mixes. 3. Revised Seed mixture numbers to agree with MnDOT's revised specifications. 4. Added street design information such as a. Minimum horizontal and vertical curves shall be design for a minimum of 30 mph in low volume urban areas. 90' horizontal curves may be used as directed by the City Engineer. C:\Users\TamiWppData\Local\Microsoft\Windows\Temporary Intemet Files\Content.Outtook\L723WOXW\EXHIBIT A_SUMMARY.doc W z J W CL 0 IL 8 0' 46' B - 10' 6' 12' I 12' SHOULDER THRU LANE THRU LANE SHOULDER SLOPE 1 /4" PER FT., ------------ 2% MIN. SLOPE W z J F- W 0 IL 10' BITUMINOUS TRAIL I L L B618 CONCRETE CURB (EITHER SIDE) *** L A & B BITUMINOUS MAT AND GUTTER PLACED C CLASS 5 GRAVEL BASE ON APPROVED SUBGRADE (MODIFIED) 47' WIDTH D APPROVED SUBGRADE 48' WIDTH LEGEND R VALUE SIGMA N18 BITUMINOUS SURFACE AGGREGATE BASE WEAR NON -WEAR CLASS 5 OR 6 CLASS 3 OR 4 RADE rP 2350 2350 3138 3138 CLASS LVWE45030B LVNW35030B C* D* 3 R-70 < 90,000 ** 2" ** 2 1/2" ** 5" _ A-4 R-20 <_ 90,000 2" 2 1/2" 5" - A-6 R-15 < 90,000 2" 2 1/2" 5" 12" A-7 R-10 < 90,000 2" 2 1/2" 6" 18" R-5 < 90,000) 2" 2 1/2" 6" 24„ * SUBJECT TO REVIEW BY QUALIFIED SOILS ENGINEER ** MINIMUM ALLOWABLE DESIGN THICKNESS o ***SEE STANDARD DETAIL 707 NOTES: R VALUE IS A MEASURE OF EMBANKMENT SOIL RESISTANCE STRENGTH AS DETERMINED BY THE HVEEM STABILOMETER METHOD SIGMA N18 VALUE IS THE CUMULATIVE DAMAGE EFFECT OF VEHICLES DURING THE DESIGN LIFE OF A FLEXIBLE PAVEMENT. Lu MSA COLLECTOR Ew " URBAN STREET SECTION — 10 TON a� r0 NO SCALE r m I Lo p APPROVED CITY OF Seo STANDARD PLATE REVISED 103 Q 8-18-15 MINNESOTA Y IW TEMPORA EASEMENT SEPER/ DOCUMENT SH/ COVER ALL CUL-DE-5 BEYOND PLATI RIGHT-OF-Vv BACK OF 4 BITUMINOUS CURB END OF CONCRETE CURB TEMPORARY CUL DE SAC URBAN SECTION NO SCALE PROPERTY LINE ROW LINE APPROVED CITY OF O STANDARD PLATE N0. I 0 o REVISED U 8/18/15 MINNESOTA 0 Q� Y In w APP 100' z 55' B-B I Iw 5.5' 10' 7' 12' 14 12 I C SHOULDER THRU LANE CENTER TURN THRU LANE SHOULDER LANE I SLOPE 1 4' PER FT... 2% MIN. SLOPE 10' BITUMINOUS TRAIL A & B BITUMINOUS MAT B618 CONCRETE CURB (EITHER SIDE)*** L C CLASS 5 GRAVEL BASE AND GUTTER PLACED (MODIFIED) 56' WIDTH ON APPROVED SUBGRADE D APPROVED SUBGRADE 57' WIDTH LEGEND AASHTP R VALUE SIGMA N18 BITUMINOUS SURFACE AGGREGATE BASE WEAR NON -WEAR CLASS 5 OR 6 CLASS 3 OR 4 SUBGRADE 2350 2350 3138 3138 SOIL CLASS LVWE45030B LVNW35030B C* D* A-3 R-70 < 90,000 ** 2" ** 2 1/2" ** 5" - A-4 R-20 <_ 90,000 2" 2 1/2' 5" - A-6 R-15 < 90,000 2" 2 1/2" 5" 12" 18" A-7 R-10 < 90,000 2" 2 1/2" 6" 24" R-5 < 90,000) 2" 2 1/2" 6" 8-18-15 * SUBJECT TO REVIEW BY QUALIFIED SOILS ENGINEER ** MINIMUM ALLOWABLE DESIGN THICKNESS ***SEE STANDARD DETAIL 707 NOTES: R VALUE IS A MEASURE OF EMBANKMENT SOIL RESISTANCE STRENGTH AS DETERMINED BY THE HVEEM STABILOMETER METHOD SIGMA N18 VALUE IS THE CUMULATIVE DAMAGE EFFECT OF VEHICLES DURING THE DESIGN LIFE OF A FLEXIBLE PAVEMENT. INDUSTRIAL COLLECTOR URBAN STREET SECTION — 10 TON NO SCALE ottCITY OF STANDARD PLATE se 113 MINNESOTA VIE 0 w 0 z (N N w J z m w 0 m KWC HYDRANT LOCATOR ROD (FULLY WRAPPED FIBERGLASS) 5 FT LENGTH RED/WHITE WITH STAINLESS STEEL SPRING MOUNT 2 1 /2" HOSE CONNECTION 4 1 /2" PUMPER CONNECTION 10 w w NOTES: vwi 0 N 1. 22" BREAKOFF SECTION z 2. LEFT HAND OPERATING NUT 3. PAINT BARREL SECTION RED TO GRADE 4. DRAIN HOLES ABOVE NORMAL WATER TABLE TO BE OPEN, DRAIN HOLES NOMINAL BELOW NORMAL WATER TABLE TO BE GROUND PLUGGED. HYDRANTS WITH PLUGGED LINE DRAIN HOLES SHALL BE TAGGED WITH 8 3/$ A METAL STRIP AND THE NOZZLE PAINTED BLACK 5. ALL CAPS SHALL BE FITTED WITH STANDPIPE CHAINS. 6. ALL BELOW GROUND NUTS AND BOLTS BOTTOM SHALL BE CORE -BLUE OR 316 STAINLESS STEEL 0 N w PACER TRAFFIC FLANGE HYDRANT 0 (OR APPROVED EQUAL) CD a� NO SCALE N 0 r I Lo p o APPROVED CITY OF STANDARD PLATE 61 tSe 0 o REVISED 203 O� U oo Q 8-18-15 MINNESOTA Y N0. 5'-0" APPROVED LOCATOR ROD HYDRANT MARKER HEIGHT OF VALVE BOX TO PACER TRAFFIC FLANGE HYDRANT BE ADJUSTED TO FINISHED O° OR APPROVED EQUAL GRADE ABOVE CURB 122" 4% 2„ � VALVE LOCATION 2' FEET FROM BACK OF CURB L UNDISTURBED SOIL EXTENSION ROD 3,-0" 18" MINIMUM SEPARATION FROM STORM SEWER W/ ' INSULATION MIN. 2 LAYERS OF HYDRANT DRAIN PLASTIC 4 MIL. WATERMAIN MIN. THICKNESS CRUSHED ROCK -" 1 CU. YD. CONCRETE THRUST BLOCK & BASE 3 TIE BACK THE VALVE 018" NOTES: MINIMUM 1. HYDRANT DRAINS BELOW WATER TABLE TO N SEPARATION FROM BE PLUGGED AND THE HYDRANT TAGGED SANITARY SEWER WITH METAL STRIP AND THE NOZZLE Ln PAINTED BLACK. 2. ALL BELOW GROUND NUTS, BOLTS, AND W nr�I RODDING SHALL BE CORE —BLUE OR 316 STAINLESS STEEL. o Ew �0 �o HYDRANT AND VALVE INSTALLATION '� U) NO SCALE I Lno o N o�0o APPROVED CITY OF tse (*' STANDARD PLATE No. o REVISED 204 � U Q 8-15-15 MINNESOTA Y wi �IW ADJUST TO FINISHED FINISHED GROUND AS SPECIFIED GRADE VALVE BOX ASSEMBLY w O 0 BASE, VALVE & BLOCKS Lo TO BE WRAPPED WITH 2 LAYERS OF 4 MIL PLASTIC ZD z 2 SOLID CONCRETE BLOCKS WATERMAINMIN 4" THICK SIZE VARIES MIN 8" X 12" SOLID CONCRETE BLOCKS MIN 4" THICK MIN 8" X 12" NOTES: 1. ALL VALVES SHALL BE FITTED WITH EXTENSION STEMS. TO BRING THE OPERATING NUT TO BE 2' FROM THE SURFACE. 2. ALL BELOW GROUND NUTS, BOLTS, AND RODDING SHALL BE CORE -BLUE OR 316 STAINLESS STEEL. TYPICAL RESILIENT WEDGE VALVE & BOX INSTALLATION 10" & UNDER WATERMAIN NO SCALE APPROVED CITY OF STANDARD PLATE NO. 0 o REVISED tse U 0 205 8-18-15 ADJUST TO FINISHED GROUND AS SPECIFIED 2 SOLID CONCRETE BLOCK MIN 4" THICK MIN 8" X 12" FINISHED GRADE 'E BOX ASSEMBLY SOLID CONCRETE BLOCK MIN 4" THICK MIN 8" X 12" NOTES: 1. ALL VALVES SHALL BE FITTED WITH EXTENSION STEMS TO BRING THE OPERATING NUT TO BE 2' FROM THE SURFACE. 2. ALL BELOW GROUND NUTS, BOLTS, AND RODDING SHALL BE CORE —BLUE OR 316 STAINLESS STEEL 3 O N TYPICAL BUTTERFLY VALVE & W 12 BOX INSTALLATION & " 0 OVER WATERMAIN o NO SCALE Lo I � o APPROVED CITY OF uI STANDARD PLATE tse 206 o REVISED Q U 0 8-15-15 MINNE80TA Y NO. c6 0 N W O CD f W d F O 63 W 0 Q� V WATERTIGHT FRAME AND CASTING TO BE NEENAH R-1642, HAMILTON KENT LIFESPAN SYSTEM, OR 4" TOPSOIL APPROVED EQUAL. SEED & MULCH ADJUSTING RINGS 1 Z PER STD PLATE 309 FLEXIBLE o ;" WATERTIGHT I STEPS AS SLEEVE `n PER STANDAR DRAIN PLATE 48" I.D. PRECAST CONC. MANHOLE SECTIONS WITH APPROVED N ? / STEPS PER Mn/DOT PLATE REPLACE & COMPACT NO. 4180J EXCAVATED MATERIAL 8" PRECAST BASE RING GEOTEXTILE FILTER of Y}'<< 1Y2 DIAMETER oc,IGckr;-,r,cov oc-' CRUSHED ROCK �- 7'-0" SQ (NO FINES) SEEPAGE PIT DETAIL NO SCALE APPROVED CITY OF REVISED otS�j 8-18-15 MINNESOTA STANDARD PLATE NO. 208 E a N 0 N rn ADJUSTING RING(S) PER STD PLATE 309 ALL OTSEGO SANITARY MANHOLES MOISTURE PROOF BOTH SIDES CONSEAL CS-55 (GRAY) OR APPROVED EQUAL. DO NOT COAT RUBBER GASKETS OR BOOTS GASKET (SPEC. 3726 TYPE B) OR APPROVED EQUAL RUBBER WATERPROOF 7.. GROUT BOTTOM TO SLOPE TOWARD PIPE AS SHOWN BY ARROWS FORM 1/2 PIPE SECTION OF LARGEST DIAMETER PIPE SECTION A -A FRAME AND CASTING PER STD PLATE 307 EXTERNAL CHIMNEY SEAL PER STD PLATE 310 27" PRECAST ECCENTRIC REDUCER SECTION POSITION OPENING AND STEPS ON DOWN STREAM SIDE 5" 1 6"O.0 MAXIMUM DISTANCE FROM RIM TO FIRST STEP IS 24" - APPROVED STEPS PER MN/DOT PLATE NO. 4180 J WALLS TO BE CONSTRUCTED OF PRECAST SECTIONS WITH R-4 JOINTS. GASKETS REQUIRED FOR JOINTS FROM 3' ABOVE PIPE INSERTS WATER TABLE AND BELOW SHALL BE SEALED (SEE STD PLATE 314) 6" BASE OR INTEGRAL BASE FOR FL W ALL MANHOLES LESS THAN 14 FT 3 DEEP INCREASE BASE 2" PER 6 FT CONCRETE SLAB - OF DEPTH BEYOND 14 FT GROUT FLOW LINE MANHOLE INVERT SHALL 1 MANHOLE NOTES: AS SHOWN ABOVE o BE SLOPED TO PROVIDE n SMOOTH FLOW FROM REINFORCING SHALL BE A MINIMUM OF A n INLET TO OUTLET SINGLE LINE WIRE FABRIC HAVING AN AREA OF NOT LESS THAN 0.12 SQ. IN. r PER FT. OF HEIGHT. CASTING AND PRECAST RINGS ALTERNATE n (WHEN REQUIRED) SHALL BE SET ON A - FULL MORTAR BED. SANITARY SEWER STANDARD MANHOLE O Q) NO SCALE APPROVED �I ! CITY OF se O ot STANDARD PLATE NO. 300 o REVISED 8-18-15 �' OTA GROUT BOTTOM TO SLOPE TOWARD PIPE AS SHOWN BY ARROWS STEPS MUST BE ROTATED 30° AROUND DROP SECTION a" _ o ° a FORM 1/2 PIPE SECTION OF ° LARGEST DIAMETER PIPE PLAN VIEW FRAME AND CASTING PER STD PLATE 307 EXTERNAL CHIMNEY SEAL PER STD PLATE 310 e PRECAST ECCENTRI, REDUCER SEC STEPS AS PER - STANDARD PLATE 5" ADJUSTMENT RING(S) PER STD PLATE 309 . rMAXIMUM DISTANCE FROM RIM TO FIRST STEP IS 24" APPROVED STEPS PER MN/DOT PLATE NO. 4180 J e d. WALLS TO BE CONSTRUCTED OF PRECAST SECTIONS WITH R-4 JOINTS DUCTILE IRON PIPE FROM TEE RUBBER BOOT TO UNDISTURBED SOIL MIN. 10 FT :j I I TEE D.I.P. I I ° 1 6" O.C. - UNDISTURBED SOIL TRANSITION TO PVC PIPE BY a JOINTS FROM 3' ABOVE - APPROVED WATER TABLE AND BELOW a. D.I.P. RISER METHOD ri SHALL BE SEALED (SEE STD PLATE 314) 4'-0" -----PRECAST HORSESHOES RUBBER BOOT ° _ TO BE USED TO d : ENCASE DROP PIPE. ° FILL WITH CONCRETE a NOTE: Ld I ° ALL OTSEGO SANITARY MANHOLES MUST BE o d °. MOISTURE PROOF INSIDE AND OUT WITH CD MANHOLE INVERT SHALL BE ° v° d ° CONSEAL CS-55 (GRAY) ~o SLOPED TO PROVIDE SMOOTH OR APPROVED EQUAL. DO NOT COAT GASKETS OR RUBBER BOOTS. FLOW FROM INLET TO OUTLET STANDARD MONOLITHIC DROP MANHOLE o NO SCALE APPROVED CITY O F ot STANDARDPLATEN0. o REVISED 0 8-18-15 NEENAH R-1642, HAMILTON KENT LIFESPAN SYSTEM, OR APPROVED EQUAL. WORDS "SANITARY SEWER" IMPRINTED ON COVER. PLACE BUTYL SEALANT AROUND EACH ANCHOR BOLT IN EACH ADJUSTMENT RING. ADJUSTING RING(S) PER STD PLATE 309. PLACE TWO 1/2" BEADS OF BUTYL SEALANT BETWEEN FIRST ADJUSTMENT RING AND CONCRETE STRUCTURE. ONE BEAD BETWEEN EACH SUBSEQUENT RING AND FRAME 27" CAST IRON EXTENSION RING INSTALLED WITH SEALANT PER MANUFACTURES RECOMMENDATIONS EXTERNAL CHIMNEY SEAL PER STD PLATE 310. THREADED INSERT TO ACCEPT 1/2" BOLT OR RODDING. EMBEDDED INTO TOP OF CONCRETE MANHOLE CONE AT LEAST 3". 4 EACH TO MATCH FRAME ON 33" BOLT CIRCLE MANHOLE CONE STANDARD MANHOLE FRAME AND CASTING (ALL MANHOLES EXCEPT WHERE WATERPROOF FRAMES AND CASTINGS ARE REQUIRED) NEENAH R-1755—F2, HAMILTON KENT LIFESPAN SYSTEM, OR EQUAL. WORDS "SANITARY SEWER" IMPRINTED ON OUTER COVER INNER LID "U" IRON EZ STICK MASTIC THREADED INSERT TO ACCEPT 3/4" OR EQUAL BOLT OR RODDING. EMBEDDED PLACE 2 BEADS INTO TOP OF CONCRETE MANHOLE CONE ATLEAST 3". 4 EACH TO MATCH FRAME ON 34 1/4" BOLT CIRCLE a GASKET 3/4" DIA. 316 STAINLESS STEEL BOLT 3 1/2" LONG. WATERPROOF FRAME AND CASTING (ALL FORCEMAIN MANHOLES, OR ANY MANHOLE WITHIN GREEN SPACES OR WITHING THE 100 YR HWL AREA) NOTE: 1. ALL NUTS, BOLTS, THREADED INSERTS, AND RODDING SHALL BE 316 STAINLESS STEEL. II 2. CLEAN ALL SURFACES TO REMOVE SCALE OR LOOSE IMPEDIMENTS BEFORE PLACING ANY MASTIC, 3 SEALANT, OR INSTALLATION OF FRAME AND CASTING SYSTEM. 3. NEENAH R-1642 SYSTEM SHALL CONSIST OF CAST IRON FRAME, SOLID CAST IRON LID, CAST IRON EXTENSION RING AND HDPE "PLASTIC" ADJUSTMENT RINGS. 4. HAMILTON KENT, LIFESPAN SYSTEM SHALL CONSIST OF ELASTOMERIC FRAME, ELASTOMERIC cn EXTENSION RING, ELASTOMERIC ADJUSTMENT RISERS AND CAST IRON LID. LID SHALL HAVE (3) THREE LOCKING CAM LUGS. TIGHTEN TO 50 FT—LBS TORQUE. 2. NEENAH R-1755-1`2 SYSTEM SHALL CONSIST OF CAST IRON FRAME, SOLID CAST IRON LID, & w INNER LID. THOUGH NOT TYPICAL IF NECESSARY HDPE PLASTIC" ADJUSTMENT RINGS SHALL no� BE USED. THE INSERT EXTENSION RINGS ARE NOT ALLOWED FOR FINAL CASTING o ADJUSTMENTS WITH THESE FRAMES AND CASTINGS. a� SANITARY MANHOLE FRAME co AND CASTING o NO SCALE U) 0 N APPROVED CITY O F �I 0 ��� O STANDARD PLATE N0. o' o REVISED Q .. 8-18-15 MINNESOTA Y a MANHOLE FRAME AND CASTING PER STD PLATE 307 MAX 4 RINGS. NUMBER OF ADJUSTMENT RINGS SHALL BE MINIMIZED TO THE EXTENT POSSIBLE, I.E. USE (2) 4" RINGS INSTEAD OF (4) 2" RINGS PLACE BUTYL SEALANT AROUND EACH ANCHOR BOLT IN EACH ADJUSTMENT RING. THREADED INSERT TO ACCEPT 1/2" BOLT OR RODDING. EMBEDDED INTO TOP OF CONCRETE MANHOLE CONE AT LEAST 3". 4 EACH TO MATCH FRAME tea. a .ad4 EXTERNAL CHIMNEY SEAL PER STD PLATE 310. PAVEMENT ail CHIMNEY HEIGHT MINIMUM 4"- MAX 16" 27" 3" MINIMUM as PRECAST MANHOLE CONE �a NOTES: 1. ALL NUTS, BOLTS, THREADED INSERTS, AND RODDING SHALL BE 316 STAINLESS STEEL. 2. ADJUSTMENT RINGS SHALL BE HIGH DENSITY POLYETHYLENE RINGS AS MANUFACTURED BY LADTECH, INC OR APPROVED EQUAL. 3. ALL RINGS SHALL MEET OR EXCEED MnDOT HS-20 TRAFFIC LOADING. 4. AS DETERMINED BY THE CITY ENGINEER, PRECAST CONCRETE ADJUSTING RINGS OR BRICK CHIMNEY WILL BE ALLOWED FOR ADJUSTING EXISTING MANHOLES. 5. CLEAN ALL SURFACES TO REMOVE SCALE OR LOOSE IMPEDIMENTS BEFORE PLACING ANY MASTIC, SEALANT, OR INSTALLATION OF FRAME AND CASTING SYSTEM. 6. PLACE TWO 1/2" BEADS OF BUTYL SEALANT BETWEEN FIRST ADJUSTMENT RING AND CONCRETE STRUCTURE. ONE BEAD BETWEEN EACH SUBSEQUENT RING AND FRAME. 8-18-15 Y MANHOLE ADJUSTMENT RINGS NO SCALE CITY OF STANDARD PLATE NO. )'o tse o 309 MINNESOTA E a rn I Lo 0 N a) Q INSPECTION TAB INFI-SHIELD EXTERNAL SEAL HDPE e ° o "PLASTIC" RINGS c a NOTES: 1. THE ADJUSTMENT RINGS AND FRAME SHALL BE SEALED WITH AN EXTERNAL RUBBER SEALING SLEEVE, "INFI-SHIELD" AS MANUFACTURED BY SEALING SYSTEM, INC. OR APPROVED EQUAL. 2. THE SEAL SHALL BE MADE OF EPDM RUBBER WITH A MINIMUM THICKNESS OF 60 MILS AND SEALED WITH A NON -HARDENING BUTYL RUBBER MASTIC. EXTERNAL CHIMENY SEAL (ALL NEW MANHOLES) 3 NO SCALE 0 I 0 0 LO w I O 0 w cn H O cn 0 0 APPROVED CITY OF STANDARD PLATE NO. tse o REVISED 0 310 U 8-18-15 MINNESOTA Y LOCATE OPENING IN AIR/VACUUM VALVE POSITION SHOWN CORE DRILL FOR FORCEMAIN WATERTIGHT BOOT 12" DIAMETER SUMPT LEEVE SLEEVE |N `\� `—FORCE�A ALL PIPES AT VARYING D|AWETER —~ | WALLS— (TYPICAL) MANHOLE FRAME AND CASTING TO BE NEENAH R-1755—F2, HAMILTON KENT LIFESPAN EXISTING GROUN7 SYSTEM, OR APPROVED EQUAL. SEE STD PLATE 307 MAXIMUM DISTANCE FROM RIM TO FIRST STEP IS 24" APPROVED STEPS PER MnDOT PLATE NO. 4180 J PRECAST ECCENTRIC REDUCER SECTION WALLS TO BE CONSTRUCTED OF PRECAST SECTIONS WITH R-4 JOINTS. JOINTS FROM 3' ABOVE TER TABLE AND ALL OTESGO MANHOLESBELOW SHALL BE SEALED (scs STD PLATE MUST BE MOISTURE 314) PROOFED WITH RUBBER WATERPROOF S REQUIRED FOR GASKET OR APPROVED EQUAL SLEEVE PIPE INSERTS SLEEVE /« 12.STEEL PIPE SUPPORT FORCEMA|NREINFORCED —' CONCRETE BASE TAPPING SADDLE D'' —/ |`-12" DIAMETER SUMP WITH AIR/VACUUM VALVE, / (8" DEEP) BALL VALVE AND BACK FLUSHING ASSEMBLY SECTION B-B NOTE: ARRANGE PIPE JOINTS TO BE AT LEAST SIX FEET FROM CENTER OF MANHOLE. E 0 _ � / m APPROVE[ c\4 _REVISED � < FORCEMAIN AIR/VACUUM VALVE NO SCALE CITY OF MINNESOTA ��T��J[l���[� PLATE W(� ~^''`'"^^'`'`^` ' �'`'^— '`^^^ � �. �1� TEE CORE DRILL FOR WATERTIGHT BOOTS\ TEE � VARYING DIAMETER MANHOLE FRAME AND CASTING TO BE NEENAH R-1755-F2, HAMILTON KENT LIFESPAN SYSTEM, OR APPROVED EQUAL. SEE STD PLATE 307 PRECAST ECCENTRIC REDUCER SECTION ALL OTESGO MANHOLES - MUST BE MOISTURE PROOFED WITH CONSEAL CS-55 (GRAY) OR APPROVED EQUAL 12" FORCEMAIN DIP TEE WITH 8" GATE VALVE AND BLIND FLANGE ON PVC FORCEMAIN FOR VACUUM TRUCK HOSE CONNECTION A N I o REVISED U 8-18-15 Y LOCATE OPENING IN POSITION SHOWN -12" DIAMETER SUMP FORCEMAIN B WATERTIGHT BOOTS ALL PIPES AT WALLS (TYPICAL) EXISTING GROUN MAXIMUM DISTANCE FROM RIM TO FIRST STEP IS 24" APPROVED STEPS PER MnDOT PLATE NO. 4180 J WALLS TO BE CONSTRUCTED OF PRECAST SECTIONS WITH R-4 JOINTS. JOINTS FROM 3' ABOVE WATER TABLE AND BELOW SHALL BE SEALED (SEE STD PLATE 314) RUBBER WATERPROOF GASKETS REQUIRED FOR PIPE INSERTS ADJUSTABLE STEEL PIPE SUPPORT REINFORCED ' CONCRETE BASE 8' 12 DIAMETER SUMP (6" DEEP) SECTION B-B NOTE: 1. ARRANGE PIPE JOINTS TO BE AT LEAST SIX FEET FROM CENTER OF MANHOLE 2. CLEAN OUTS ARE TYPICALLY LOCATED AT LOW POINTS IN FORCE MAIN AND WITH GAVE VALVES ON BOTH SIDES OF MANHOLE. FORCEMAIN CLEANOUT NO SCALE CITY OF STANDARD PLATE NO. Sego 313 MINNESOTA E Ln i Lo 0 N 1 FORM 1 /2 PIPE SECTION OF LARGEST DIAMETER PIPE I I GROUT BOTTOM TO SLOPE TOWARD PIPE AS SHOWN BY ARROWS SECTION A -A MANHOLE COVER SHALL FRAME & CASTING (SEE BE TYPE II WITH 27" MH & CB SCHEDULE). ECCENTRIC OPENING. 00 0 ' STEPS 16" O.C.- APPROVED STEPS PE MN/DOT STANDARD PLATE 4180J A VARIES �, SEAL PIPES WITH GROUT ADJUSTING RINGS) PER STD PLATE 414 MAXIMUM DISTANCE FROM RIM TO FIRST STEP IS 24". MANHOLE TO BE CONSTRUCTED OF PRECAST CONCRETE SECTIONS MIN. CLASS III REINFORCEMENT, JOINTS SHALL BE CONSTRUCTED WITH CONFINED 0—RING GASKETS. ' A PRECAST OR CAST IN PLACE LOWER SECTION POURED OR PRECAST CONCRETE MANHOLE BASE. I r SLOPED TO PROVIDE SMOOTH ::),I FLOW FROM INLET TO OUTLET. n BASE 6" — 12 ft DEEP SLAB -TOP MANHOLE 8" — 12 ft TO 20 ft DEEP (STORM SEWER) 10" — OVER 20 ft DEEP NO SCALE cy APPROVED CITY OF �I � ot � STANDAR400LATE N0. oREVISED 8-18-15OTA Y FORM 1 /2 PIPE SECTION OF LARGEST DIAMETER PIPE all GROUT BOTTOM TO SLOPE TOWARD PIPE AS SHOWN BY ARROWS SECTION A —A FRAME & CASTING (SEE MH & CB SCHEDULE). ADJUSTING RINGS) PER STD PLATE 414 PRECAST ECCENTRIC REDUCER SECTION Z 27" MAXIMUM DISTANCE FROM RIM o TO FIRST STEP IS 24". 16"O.C. 5" SEAL PIPES WITH GROUT A I I IFLbw I 10.10 I I 3" MIN. STEPS AS PER MN/DOT STANDARD PLATE 4180J MANHOLE TO BE CONSTRUCTED OF PRECAST CONCRETE Lj SECTIONS MIN. CLASS III a REINFORCEMENT, JOINTS SHALL BE CONSTRUCTED WITH > CONFINED 0-RING GASKETS. A MIN. ::- 6" BASE FOR ALL MANHOLES E 5'-4" LESS THAN 14 FT. DEEP INCREASE BASE 2" PER 6 FT. MANHOLE INVERT SHALL BE CONCRETE SLAB OF DEPTH BEYOND 14 FT. 5" zi SLOPED TO PROVIDE SMOOTH PRECAST BASE MAY BE USED O FLOW FROM INLET TO OUTLET FOR MANHOLES LESS THAN 14 FT. DEEP Y) d0 STORM SEWER STANDARD MANHOLE u- NO SCALE APPROVED TY OF STANDARD PLATE NO. o REVISED ot§go 401 8-18-15 oto MINNESOTA Ln 0 i E i 1 1/2" MIN-' REINFORCEMENT CLEARANCE COVER SLAB Mn/DOT 4022A TOP OF CURB FLOW oc LINE w — J L m - F- a_, (oil W CL (n < � H � N Q U L,J Z w0:�a F A MINIMUM OF THREE APPROVED HANDLING DEVICES AT 120° SPACING. A CASTING NEENAH 3067 OR EQUIVALENT WITH DL OR DR GRATE SECTION A -A ADJUSTING RINGS) PER STD PLATE 414 STRUCTURE Mn/DOT PLATE 4024A GROUT INVERT AS REQUIRED MINIMUM C.B. DEPTH - FLOW LINE TO INVERT PIPE DIA. MIN. DEPTH MINIMUM DEPTH WITH 2 RINGS 15 41 IN. 41 IN. 18 45 IN. 45 IN. 21 48 IN. 48 IN. 24 51 IN. 51 IN. 0 Ew aU) O 0 L� Lo 0 o APPROVED N � N o REVISED 8-18-15 Q .. Y GROUT INVERT STANDARD OPENINGS PIPE DIA. (IN.) OPENING SIZE (IN.) 15 24 18 26 21 30 24 34 48 INCH DIAMETER SHALLOW DEPTH CATCH BASIN MAXIMUM 24 INCH DIAMETER PIPE SIZE NO SCALE ottCITY OF STANDARD PLATE NO. se 405 MINNESOTA 1 FORM 1/2 PIPE SECTION OF LARGEST DIAMETER PIPE ' CASTING NEENAH 3067 OR EQUIVALENT WITH DL OR DR GRATE TOP OF CURB FLOW n Z LINE `O m 00 Lo —4/291 MAXIMUM DISTANCE FROM RIM TO FIRST STEP IS 24" GROUT BOTTOM TO SLOPE TOWARD PIPE AS SHOWN SECTION A -A BY ARROWS Lo STEPS AS PER 5" Y j MN/DOT STANDARD ,{.r / PLATE 4180J ADJUSTING RINGS) PER STD PLATE 414 COVER SLAB Mn/DOT 4022A RECAST SEGMENTS AS EQUIRED IN 1 FOOT IULTIPLES 48" 16" O.C. PRECAST LOWER SECTION A SEAL PIPE x MINIMUM 36" HIGH MAXIMUM WITH GROUT 48" HIGH Mn/DOT PLATE 4005L LOWER SECTION E I 4'-O" NOTES: `— 5'-4" MANHOLE INVERT SHALL BE REINFORCING: SLOPED TO PROVIDE SMOOTH W SINGLE LINE STEEL WIRE FABRIC FLOW FORM INLET TO OUTLET. o HAVING AN AREA OF NOT LESS THAN (SEE SECTION A —A) W 0.12 SQ. IN. PER FOOT OF HEIGHT. STANDARD STORM MANHOLE — CATCH BASIN d MINIMUM COVER FLOW LINE - TO TOP OF PIPE = 2 FEET NO SCALE APPROVED CITY OF t�� o STANDAR406LATE N0. Io Ag o REVISED U 8-18-15 MINNESOT E O (D L6 i Lo 0 N Q� 1 FORM 1 /2 PIPE SECTION OF LARGEST DIAMETER PIPE ' I � ~I I t GROUT BOTTOM TO SLOPE TOWARD PIPE AS SHOWN SECTION A -A BY ARROWS CASTING NEENAH R-4342) OR EQUIVALENT STOOL TYPE GRATE _ MAXIMUM DISTANCE - FROM RIM TO FIRST STEP IS 24". n Do 0 i E ADJUSTING RINGS) PER STD PLATE 414 W W (D STEPS AS PERd 5" MN/DOT STANDARD PLATE 4180J STEPS 1 6"O.C. 48" ' SEAL PIPE 9 WITH GROUT a. 4'-0" NOTES: 5'-4" Lo REINFORCING: w SINGLE LINE STEEL WIRE FABRIC 1 HAVING AN AREA OF NOT LESS THAN o 0.12 SQ. IN. PER FOOT OF HEIGHT. COVER SLAB Mn/DOT 4020J MANHOLE INVERT SHALL BE SLOPED TO PROVIDE SMOOTH FLOW FROM INLET TO OUTLET w STANDARD STORM MANHOLE -YARD INLET NO SCALE 0 Q)lAPPROVED CITY OF 0 STANDARD 408 LATE N0. o REVISED U 0 8-1 8-1 5 MINNE80TA E CD 0 L6 i 0 N GROUT BOTTOM TO SLOPE 5" / TOWARD PIPE AS SHOWN BY ARROWS. A A / f ��q }_ L PIPE TOP VIEW ®R CASTING NEENAH R-4342 OR EQUIVALENT STOOL TYPE GRATE ADJUSTING RINGS) PER STD PLATE 414 NOTES: AS AN OPTION, BRICK OR CONCRETE BLOCK MASONRY MAY BE USED. 27ff SEAL PIPE FOR MATERIALS AND CONSTRUCTION WITH GROUT METHODS. SEE STANDARD PLATE 4002. CONE SECTION DETAILS OF 4002 DO NOT APPLY. GROUT INVERT AS SHOWN ABOVE REINFORCING: SLOPE SINGLE LINE STEEL WIRE FABRIC / Fr. HAVING AN AREA OF NOT LESS THAN 0.12 SQ. IN. PER FOOT OF HEIGHT. D a. 8" POURED CONC. BASE 2,f FOR ALTERNATE PRECAST i 44" DIA. CONCRETE BASE, SEE ;, STANDARD PLATES INDEX. n SECTION A -A BASE REINFORCEMENT: 0.12 SQ. IN. PER FOOT r I IN EACH DIRECTION. n 27" PRECAST CATCH BASIN YARD INLET NO SCALE APPROVED I 4 ON TY OF 0STANDARD PLATE NO. o REVISED Pj O Y 409 8-18-15 �` MINNESOTA E L0 O Lh i Lo 0 N 7 GROUT BOTTOM TO SLOPE TOWARD PIPE AS SHOWN BY ARROWS. A A PIPE a TOP VIEW CASTING NEENAH 3067 OR EQUIVALENT WITH DL OR DR GRATE ADJUSTING RINGS) PER STD PLATE 414 WALL TO BE PRECAST SECTION OR CONCRETE o � SEWER BLOCK Ca 24" X 36" 4 PRECAST OPENINGS a a SEALGROUT ~ AS REQUIRED e: GROUT INVERT AS �f °4 SHOWN ABOVE 13"1 RECTANGULAR 3'-6" X 4'-6" SECTION A -A NOTES: 1. CONCRETE BASE SHALL BE 6" POURED IN PLACE OR E 5" PRECAST SLAB. y 2. REINFORCING SHALL BE SINGLE LINE STEEL WIRE FABRIC r HAVING AN AREA OF NOT LESS THAN 0.12 SQ. IN. PER FOOT OF HEIGHT. 2' x 3' CATCH BASIN �I NO SCALE CITY OF O STANDARDPLATENO. o REVISED U rr 8-18-15 MINNfiSOTA Y E a I Lo 0 N FRAME & CASTING PER MH & CB SCHEDULE CONCRETE ENCASED PAVEMENT ADJUSTING RINGS Mn/DOT PLATE 4026A d MAX 4 RINGS. MAX 1" CHIMNEY GROUT PER JOINT. ° HEIGHT UMBER OF ADJUSTMENT MINIMUM 4"— RINGS SHALL BE MAX 16" MINIMIZED TO THE e . 27 a • EXTENT POSSIBLE, I.E. ` USE (2) 4" RINGS INSTEAD OF (4) 2" RINGS `a A 1^-r r"c-. 1. PRECAST CONCRETE OR BRICK CHIMNEY RINGS MAY BE USED FOR ALL CATCH BASINS, EXISTING STORM MANHOLES, AND ANY NEW MANHOLES OUTSIDE OF PAVED AREAS. 2. STORM MANHOLES WITHIN PAVED AREAS SHALL USE HDPE "PLASTIC" RINGS AND CONFORM TO STD PLATE 309 i 3. CONCRETE ENCASED ADJUSTING RINGS Mn/DOT PLATE 4026A cn 4. SHIMS USED FOR LEVELING SHALL BE METAL OR CONCRETE 0 0 w cn STORM MANHOLE ADJUSTMENT RINGS o NO SCALE a) ArrKUVtu CITY OF STAN DAR414 LATE N0. REVISED o U 8-18-15 �"� MINNESOTA Y E N L6 0 N Q el POUR CONCRETE COLLAR AROUND FES a. a OD CONCRETE BLOCK 1 0' 0 TO ANCHOR BLOCKS OD i OD GEOTEXTILE FABRIC (2 SEC. B-B BLOCK SHALL DO OD BE BACKFILLED W/TOPSOIL MCI UDO NOTE: 2, o 0 0 DIMENSION E IS GIVEN ON o 0 0 0 STD. PL. 3100 & 3110. o 0 0 0 0 0 0 0 o a o 0 0 0 0 w� oocL o 0 0 0 0 tn 1 ST ROW OF o 0 0 0 0 0 0 BLOCK SHALL ,j o BE "KEYED" IN 2 0 0 0 0 0 0 0 AT TOP AND o 0 0 0 0 ALONG EDGES o 0 o O B 5D USE EQUIV. D FOR PIPE ARCH (SEE O D. PL. 3110 FOR EQUIV. D) CONCRETE BLOCK 1.0' GEOTEXTILE FABRIC 02 SEC A -A ARTICULATED CONCRETE BLOCK SHALL BE A HANDPLACED INTERLOCKING CONCRETE ' BLOCK SYSTEM, CABLE CONNECED CONCRETE BLOCK MAT, OR APPROVED EQUAL. 1) FOR PIPES GREATER THAN OR EQUAL TO 48", USE 2.0' n 2� GEOTEXTILE FABRIC PER Mn/DOT SPEC. 3733. FABRIC SHALL BE OVERSIZED A r MINIMM OF 12" AND COVER THE ENTIRE AREA UNDER THE BLOCK MAT AND EXTEND o UNDER THE CULVERT APRON 3 FEET. D IF A CABLE CONCRETE SYSTEM IS USED, MULTIPLE MATS MUST BE TIED TOGETHER PER MANUFACTURERS SPEC. AND ALL CABLES PROTRUDING BEYOND THE FINISHED N EDGES SHALL BE CUT FLUSH TO THE BLOCK. ARTICULATED CONCRETE BLOCK AT R.C.P. OUTLET o NO SCALE APPROVED CITY OF QI STANDARD PLATE NO. o REVISED tse 0 500 0 i 8-18-15` MINNESOTA E 0- 0) N Ln 0 N m A 5.0 i 3 FACE OFJJ A CURB 5 p 5 p 5.0 PLAN VIEW OF RAMP ROUND ALL SLOPED APPROX. 10:1 SLOPE INTERSECTIONS � TOP OF CURB ELEVATION OF RAMP 5$ 4" U CURB OR CURB 1" PER FT. OR FLATTER DESIGN STREET GUTTER GRADE 1/2" PREFORMED CONCRETE WALK JOINT FILLER AASHTO M213 SECTION A -A CT a 0 1, ADA REQUIRED TRUNCATED DOME AREA SHALL BE CAST IRON INSERTS AND SHALL COMPLY WITH Mn/DOT STANDARD PLATE NO. 7038A. PRECAST TRUNCATED DOME INSERTS SHALL BE DARK GRAY IN COLOR TO VISUALLY CONTRAST WITH THE ADJACENT SIDEWALK. THE CURB ADJACENT TO THE TRUNCATED DOME INSERTS SHALL BE HAND FORMED SUCH THAT NO GAP EXISTS AS A RESULT OF THE CURVATURE OF THE � BACK OF CURB. 0I 2. VARIES WITH CURB HEIGHT. EXAMPLE SHOWN IS FOR 6" CURB HEIGHTS. w cn 0 N PEDESTRIAN CURB RAMP .o 0 NO SCALE APPROVED CITY OF 01 0 STANDARDPLATEN0. o REVISED 8-18-15` MINNESOTA ;_ co rq if7 O N rn ,oi ooc-C�:-RRm SLOPE — 3.0" BITUMINOUS MAT SECTION A —A NO SCALE 3 FT. TRANSITION1 10 FT. i CONCRETE APRON DROP CURB -- A i 2-2'X4' CAST IRON TRUNCATED DOME PEDESTRIAN RAMP INSERTS 3 FT. TRANSITION 10 FT. TYPICAL DROP CURB — BIKE TRAIL NO SCALE „ �•�� CITY OF STANDARD PLATE No. o REVISED tse O 706 8-18-15' MINNE50TA 3 0 DO z 0 r w I 0 CD w F 0 O ail v BRACKETS AS DIRECTED BY ENGINEER Lo - V)r, w J Z O = Z ~ STREET SIGNS SECONDARY SIGN POST SHALL BE PLACED IN A 12" DIA. X 2' DEEP HOLE FILLED WITH CONCRETE FURNISH AND INSTALL NEW SIGNS SIGN NUMBER SIGN COLOR SIZE COMMENTS R1-1 STOP ON WHITE RED 30% 30" STREET NAME WHITE ON GREEN g" PLATES ALL INTERSECTIONS NOTES: POSTS SHALL BE CYLINDRICAL TUBE STEEL POSTS, THE POST SHALL BE 12' LONG, WITH 2-3/8" OD, 12 GAUGE COLD ROLLED GALVANIZE STEEL MEETING ASTM A-446 GRADE A. SIGN BASE MATERIAL SHALL BE ALUMINUM. THE STREET NAME SIGNS SHALL BE NOTCHED AND MOUNTED IN AN E450 BRACKET AND PLACED ABOVE THE STOP SIGN. STREET NAME SIGNS SHALL HAVE HIGH INTENSITY PRISMATIC RETROREFLECTIVE SHEETING (ASTM TYPE IV). STOP SIGNS SHALL HAVE DIAMOND GRADE VIP RETROREFLECTIVE SHEETING (ASTM TYPE IX). SIGNS AND INSTALLATION OF SIGNS SHALL BE IN ACCORDANCE WITH THE "MINNESOTA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" STO P AND STREET NAME `. QUAIL NO SCALE APPROVED CITY OF STANDARD PLATE NO. 0 REVISED 805 8-18-15 0 MINNBSOTf� F. r- 0 i J a Lo Ew aN o� �o Ln u) . 'o a) Lo 0 o APPROVE[ CV N o REVISED c . 8-18-15 2' CLEAR ZONE VARIES [L 10.0' 2.0% 1 PLACE ON APPROVED SUBGRADE—C 2' CLEAR ZONE I A BITUMINOUS MAT LVWE45030B B CLASS 5 GRAVEL (12' WIDE) TYPICAL SECTION - BIKE TRAIL NO SCALE LEGEND AASHTP R VALUE BITUMINOUS SURFACE AGGREGATE BASE WEAR CLASS 5 CLASS 3 OR 4 SUBGRADE 2350/2360 3138 3138 SOIL CLASS A B C A-3 R-70 ** 2.5" ** 5" - A-4 R-20 3.0" 5" - A-6 R-15 3.0" 6" - A-7 R-10 3.0" 7" - R-5 3.0" 7" 12" * SUBJECT TO REVIEW BY QUALIFIED SOILS ENGINEER **MINIMUM ALLOWABLE DESIGN THICKNESS NOTES: R VALVE IS A MEASURE OF EMBANKMENT SOIL RESISTANCE STRENGTH AS DETERMINED BY THE HVEEM STABILOMETER METHOD ot§TY OF e MINNESOTA STANDARD PLATE NO. 707 E L LH 0 N rn 2' 'TEMPORARY -C� 2 " CUL DE SA( �t 1. STREET W 1. s`EXTENDED I� I 4 4' MIN. 30" 60" TEMPORARY CUL DE SA(;' LATERAL STREET WILL BE BRACE EXTENDED IN FUTUIRE 3' _ 1 8"X 1 8" 1 RED ON BLAC SIGN NO. 3.5' X4-1 1 ° NOTES: z n TYPE E WHITE LETTERING ON GREEN BACKGROUND zi THIS SIGN SHALL BE PLACED AT THE END OF DEAD END STREET OR AS A STAND ALONE SIGN AT THE END OF A TEMPORARY CUL-DE-SAC. co TEMPORARY CUL-DE-SAC SIGN a� NO SCALE APPROVEDC @ CITY OF C� 0�I� O STANDAR806LATE N0. o REVISED v 8-18-15 MINNESOTA RESOLUTION NO.: 2015 - 59 CITY OF OTSEGO COUNTY OF WRIGHT, MINNESOTA A RESOLUTION AMENDING THE CITY OF OTSEGO ENGINEERING MANUAL. WHEREAS, the City Council adopted the City of Otsego Engineering Manual in March 1999; and, WHEREAS, the Engineering Manual establishes standards for engineering to protect health safety and welfare within the City; and, WHEREAS, the Engineering Manual outlines specific requirements, materials and standards that will be incorporated into the preparation of plans and specifications for sanitary sewer, storm sewer, water mains, trails, street construction and other improvements within the City; and, WHEREAS, it is necessary from time to time to amend the Engineering Manual to update best management practices or incorporate new procedures and technology; and, WHEREAS, this policy may be amended by the City Council at any time with such modifications effective on the date they are adopted by Resolution; and, WHEREAS, the City Engineer, Hakanson Anderson Inc., has prepared proposed amendments to the Engineering Manual attached hereto as Exhibit A; and, WHEREAS, the Public Works Subcommittee at their meeting on August 18, 2015 reviewed the proposed amendment of the Engineering Manual recommends approval; and, NOW, THEREFORE BE IT RESOLVED by the City Council of the City of Otsego that the Engineering Manual is hereby amended in accordance with Exhibit A. MOTION BY: SECOND BY: ALL IN FAVOR: THOSE OPPOSED: ADOPTED by the City Council of the City of Otsego this 12t" day of October, 2015. ATTEST: Tami Loff, City Clerk CITY OF OTSEGO Jessica L. Stockamp, Mayor 2