ITEM 3.1_attachmentReview No. 1
ENGINEERING REVIEW
Hai anson Commercial Lot
for the City of Otsego
C1Cii'Oil by
Hakanson Anderson
Submitted to: Honorable Mayor and City Council
cc: Lori Johnson, Administrator
Tami Loff, City Clerk
Dan Licht, City Planner
Andy MacArthur, City Attorney
Chad Weeks, Arrow Companies
Todd W. McLouth, P.E., Loucks Associates
Reviewed by: Ronald J. Wagner, P.E.
Brent M. Larson, P.E.
Date: January 14, 2016
Proposed
Development: Great River Centre 4th Addition — Block 1 Lot 1
Street Location A portion of the NW 1/4 of the SW 1/4 of Section 23, T121N,
of Property: R23W, South of 85th St and East of Quaday Ave
Applicant: P & F Machining
Developer: Arrow Companies
Owners of Record: City of Otsego
Purpose: Great River Centre 4th Addition — Block 1 Lot 1 is a proposed
54,400 gross square foot single light industrial building located on
6.17 acres of Outlot A of Great River Centre 3rd Addition in the
City of Otsego, Wright County, Minnesota. The proposed
development will be served with municipal water, sanitary sewer,
storm sewer, and public streets typical of an urban industrial
setting.
Jurisdictional Agencies: City of Otsego, Wright County, Minnesota Department of
(but not limited to) Health, Minnesota Department of Natural Resources, Minnesota
Pollution Control Agency, Wright Soil and Water Conservation
District.
Permits Required: NPDES, Minnesota Department of Health (water), and
(but not limited to) Minnesota Pollution Control Agency (sanitary sewer)
TABLE OF CONTENTS
INFORMATION AVAILIBLE
FINAL PLAT — completed by the City of Otsego
SCHEMATIC DESIGN SET
EXISTING CONDITIONS (C1-1)
SITE PLAN (C2-1)
GRADING PLAN (C3-1)
STORM WATER POLLUTION PREVENTION PLAN AND DETAIL (C3-2 - C3-4)
UTILITY PLAN (C4-1)
DETAIL SHEET (C8-1)
LANSCAPE PLAN (L1-1& L1-2)
HYDROLOGY/STORMWATER
SUMMARY AND/OR RECOMMENDATION
PAGE 2
C:\Users\TamiWppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\L723WOXW\ot2500-2015 PF
RVW1.doc
INFORMATION AVAILABLE
Final Plat for Great River Centre 4th Addition, by Hakanson Anderson
Original Great River Centre Information
Final Plat for Great River Centre 3rd Addition
Original Hydrology Report/Storm Sewer Design for Great River Centre, by RLK June 2006
Updated Hydrology Report/Storm Sewer Design for Great River Centre, by Hakanson Anderson
October 2009
Additional Information
City of Otsego Engineering Manual
City of Otsego Zoning and Subdivision Ordinances
National Wetland Inventory Map
PAGE 3
C:\Users\TamiWppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\L723WOXW\ot2500-2015 PF
RVW1.doc
SCHEMATIC DESIGN SET
Cover Sheet
1) Cover Sheet is required with location map, north arrow, property owner, developer name and
address, architect and engineer information, and City Engineer approval signature block.
Existing Conditions Plan (Sheet CM)
1) Final plat has only one lot and one outlot. See attached Final Plat.
2) PID, property owners name and current zoning is not shown for two of the properties
immediately to the west of the site.
3) Provide the normal and 100 year flood elevations for the regional storm pond to the east of
the property. (NWL = 856.5 and HWL = 859.4)
Site Plan (Sheet C2-1)
1) Strongly recommend moving south entrance to final location and constructing drive around
south side of building in final location to minimize future disruption and future costs.
2) Legend for pavement types should reference standard plates.
3) Add Concrete pavement to legend for area under trash and recycle bins.
Grading Plan (Sheet C3-1)
1) City requires articulating block mat, fleximat or cabled concrete rather than riprap. Basin
overflow standard plate calls rip rap in one location and articulating block in another.
SWPP Plan (Sheet C3-3 — C3-3)
1) No comments
Utility Plan (Sheet C4-1)
1) CB1 may need to be larger than 48" standard manhole due to number, location and size of
three entry and one outlet pipes. Note manhole size if larger than 48" diameter.
2) Hydrant coverage is insufficient. No hydrants shown on property.
Details (Sheet C8.1 — 8.2)
1) Heavy Duty and Light Duty Loucks Standard Plates both labeled Site 30
PAGE 4
C:\Users\TamiWppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\L723WOXW\ot2500-2015 PF
RVW1.doc
2) Loucks Standard Plate STRM-3 references Loucks STRM-4. Should reference Otsego
Standard Plate 500.
3) Otsego Standard Plate 307 is unnecessary. No sanitary manholes within lot.
4) All rip rap shall be articulated block or approved equal per Otsego Standard Plates.
5) The pavement section shall be per a geotechnical engineers recommendation. Currently date
and by on standard plates are blank.
Landscape Plan (Sheet L2.1 - L2.2)
1) No comments
HYDROLOGY/STORMWATER
1) No comments
SUMMARY AND/OR RECOMMENDATION
We recommend approval contingent upon the above comments being addressed.