ITEM 3.2_attachmentReview No. 1
A►lei 141MAN III, CCIF7AVIAUI
Hakanson Industrial Lot
for the City of Otsego
Anderson by
Hakanson Anderson
Submitted to: Honorable Mayor and City Council
cc: Lori Johnson, Administrator
Tami Loff, City Clerk
Dan Licht, City Planner
Andy MacArthur, City Attorney
Dale Emter, Director of Preconstruction, Duke Realty
Erik Miller, PE, Sambatek
Reviewed by: Ronald J. Wagner, P.E.
Brent M. Larson, P.E.
Date: January 14, 2016
Proposed
Development: Gateway North 5t" Addition
Building No. 2
Street Location 6151 Queens Ave. NE
of Property:
Applicant: Duke Realty
1600 Utica Avenue South, Suite 250
Minneapolis, MN 55416
Developer: Duke Realty
Owners of Record: Duke Realty
Purpose: Construct a 212,224 gross square foot office/warehouse
building with an additional 57,920 square foot expansion of
the building planned expansion in the future on 12.77 acres
in the City of Otsego, Wright County, Minnesota. The
proposed development will be served with municipal water,
sanitary sewer, storm sewer, and public streets typical of an
urban industrial setting.
Jurisdictional Agencies: City of Otsego, Wright County, Minnesota Department of
(but not limited to) Health, Minnesota Department of Natural Resources,
Minnesota Pollution Control Agency, Wright Soil and Water
Conservation District,
Permits Required: NPDES, Minnesota Department of Health (water), and
(but not limited to) Minnesota Pollution Control Agency (sanitary sewer)
TABLE OF CONTENTS
INFORMATION AVAILIBLE
ALTA/ACSM LAND TITLE SURVEY
FINAL PLAT AND AREA MAP
LIGHTING PLAN
SCHEMATIC DESIGN SET
EXISTING CONDITIONS (C200)
SITE PLANS (C201)
GRADING PLANS (C202)
UTILITY PLANS (C203)
EROSION CONTROL PLAN PHASE I (C204)
EROSION CONTROL PLAN PHASE II (C205)
EROSION CONTROL DETAILS (C400)
STREET AND UTILITY DETAILS (C401)
STREET AND UTILITY DETAILS (C402)
STORM SEWER AND HYDROLOGY CALCULATIONS
OTHER CONSIDERATIONS
SUMMARY AND/OR RECOMMENDATION
PAGE 2
C:\Users\TamNAppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\L723WOXW\OT2267.05 REVIEW
1WAGNER.doc
INFORMATION AVAILABLE
Final Plat for Gateway North 5th Addition, by Sambatek
Storrnwater Management Plan for Gateway North Business, dated 9/4/14, by Sambatek.
Previous Gateway North Additions' Information
Final Plat for Gateway North 4th Addition, by Sambatek
Additional Information
City of Otsego Engineering Manual
City of Otsego Zoning and Subdivision Ordinances
National Wetland Inventory Map
PAGE 3
C:\Users\Tami\AppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\L723WOXW\OT2267.05 REVIEW
1 WAGNER.doc
ALTA/ACSM LAND TITLE SURVEY
1. Storm sewer in SW corner of survey depicted flowing in wrong direction.
2. Valve missing on one of existing hydrants on Queens Ave
3. Valve shown within Queens Ave right-of-way at south end of survey but not
connected to any watermain. May be misplaced valve symbol.
FINAL PLAT
1. Gateway North 5th Addition Plat included Gateway North 2nd Addition Block 1 Lot
1 and Gateway North 4th Addition Block 1 Lots 2 and 3 due to lot changes both.
Existing assessments need to transfer to new lot designations.
2. Plat will need to be reviewed and approved by Wright County Surveyor.
LIGHTING PLAN
1. No comment
SCHEMATIC DESIGN SET -12/30/15
COVER SHEET G100
1. Reference Gateway North 5th Addition in title.
2. Add a signature line and -date line for City Engineer approval, Ronald J. Wagner,
P.E. City Engineer.
3. Plans shall be signed by a Professional Engineer.
EXISTING CONDITIONS - SHEET C200
1. The following required information is missing from the existing conditions plan:
a. Show normal and 100 year flood elevations of storm pond to east. NWL =
929.00 and HWL = 930.69
SITE PLAN - SHEET C201
1. Octagonal and Circle surrounds missing in Key Notes and Development Notes
legend.
PAGE 4
C:\Users\Tami\AppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\L723WOXW\OT2267.05 REVIEW
1 WAGNER.doc
2. Consider placing key note C for curbing at truck entrance area.
3. Install curb along north edge of asphalt of GWN5 Block 1 Lot 3.
GRADING PLAN - SHEET C202
1. Grading is shown outside of GWN5 Block 1 Lot 2 but other lots north and south
are owned by same owner.
UTILITY PLAN SHEET C203
1. Ensure watermain 7.5' bury under dry pond.
2. Hydrant coverage appears adequate.
EROSION CONTROL PLAN PHASE 1 SHEET C204
1. No Comments.
EROSION CONTROL PLAN PHASE 2 SHEET C205
1. No Comments.
EROSION CONTROL DETAILS SHEET C400
1. No comments.
STREET AND UTILITY DETAILS SHEETS 401 & 402
1. No comments.
LANDSCAPE PLANS SHEETS L200 & L201
1. No comments.
STORM SEWER CALCULATIONS
1. No Comments.
PAGE 5
C:\Users\Tami\AppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\L723WOXW\OT2267.05 REVIEW
1WAGNER.doc
OTHER CONSIDERATIONS
No Comments.
SUMMARY AND/OR RECOMMENDATION
We recommend approval contingent upon the above comments being addressed.