Loading...
ITEM 4.2_attachmentReview No. 1 11H And�erson ENGINEERING REVIEW Residential Subdivision for the City of Otsego by Hakanson Anderson Submitted to: Honorable Mayor and City Council cc: Lori Johnson, Administrator Tami Loff, City Clerk Dan Licht, City Planner Andy MacArthur, City Attorney Joe Jablonski, Lennar Robert Molstad, PE, Sathre-Berquist, Inc. Reviewed by: Ronald J. Wagner, P.E. Brent M. Larson, P.E. Date: March 3, 2016 Proposed Development: The Lahn Property Street Location A portion of Section 1, T120, R23. 247+ Acres, N of the Crow of Property: River and on either side of CSAH 36 (Rawlings Avenue NE). Applicant: Joe Jablonski Developer: Lennar 16305 36th Ave. N Suite 600 Plymouth, MN 55446 Owners of Record: Lennar Purpose: The Lahn Property is a proposed 346 single family residential homes, on 247+ acres in the City of Otsego, Wright County, Minnesota. The proposed development will be served with municipal water, sanitary sewer, storm sewer, and public streets typical of an urban setting. Jurisdictional Agencies: City of Otsego, Wright County, Minnesota Department of (but not limited to) Health, Minnesota Department of Natural Resources, Minnesota Pollution Control Agency, Wright Soil and Water Conservation District. Permits Required: NPDES, Minnesota Department of Health (water), (but not limited to) Minnesota Pollution Control Agency (sanitary sewer), and Wright County TABLE OF CONTENTS INFORMATION AVAILABLE EXISTING CONDITIONS SUBDIVISION CONFIGURATION, LOT SIZE, DENSITY STREETS PRELIMINARY PLAT TRAFFIC/ACCESS ISSUE WETLANDS SURFACE WATER MANAGEMENT SANITARY SEWER COLLECTION SYSTEM WATER DISTRIBUTION SYSTEM ENVIRONMENTAL OTHER CONSIDERATIONS SUMMARY AND/OR RECOMMENDATION PAGE 2 SAM unicipal\Aotsego23xx\2328\ot2328RVW 1.doc INFORMATION AVAILABLE ALTA/NSPS Land Title Survey, 2/15/16, by Sathre-Berquist, Inc. Preliminary Plat of The Lahn Property, 2/15/16, by Sathre-Berquist, Inc. The Lahn Property EAW Additional Information Minnesota Rules, Chapter 4410 — EAW Requirement City of Otsego Engineering Manual City of Otsego Zoning and Subdivision Ordinances National Wetland Inventory Map PAGE 3 SAM unicipal\Aotsego23xx\2328\ot2328RVW 1.doc EXISTING CONDITIONS Existing zoning classifications for land in and abutting the subdivision shall be shown on the plan. (21-6-2.B.2.) Missing all. 2. Location, size, and elevations of existing storm sewer and culverts, or any other underground facility within 150 feet of the proposed plat, shall be shown on the plan. (21-6-2.B.5.) Missing River Place 2"a/3rd Improvements. 3. Boundary lines of adjoining unsubdivided and subdivided land, identified by name and ownership, shall be shown within 150 feet of the plat. (21-6-2.B.6.) Missing all. 4. Existing 100 -year flood elevations shall be shown on the plan. (21-6-2.B.9.) Shoreland District must be shown. 5. Provide a legend. Existing well and septic systems within 150' of the preliminary plat must be shown. Parcels IV Exception Tract 1 and 2 and form yard south of CSAH 36. 6. Section corners and section lines shall be clearly depicted and labeled on the plan. (21-6- 2.A.2.) 7. Revise to Randolf Avenue NE to Randolph Ave NE on all sheets. The limits of the Shoreland Overlay District shall be shown on the plan. SUBDIVISION CONFIGURATION, LOT SIZE, DENSITY Blocks shall be less than 1,200 feet in length. (21-7-3.13) Road 13 as wells as a couple of block lengths along Road 1 slightly exceeds this. We recommend allowing these deviations due to topography considerations. 2. Principal building setbacks on Lot 104 and 153 are compromised by wetland setbacks. 3. The purpose and ownership for Outlook K is unclear. STREETS Temporary cul-de-sacs shall have a minimum 40' radius and bituminous curb. PRELIMINARY PLAT 1. Section corners and section lines shall be clearly depicted and labeled on the plan. (21-6- 2.A.2.) Completed. 2. Location, dimensions, and purpose of all proposed easements shall be shown on the plan. (21-6-2.C.5.) Completed — Temporary construction easement per Document No. 838577 Should be removed. 3. The ROW shall be rounded at intersections parallel to back of curb. (111. 13.) PAGE 4 S:\MunicipaMotsego23xx\2328\ot2328RVW1.doc 4. Normal water elevations and 100 -year peak elevations have been labeled for all ponding areas, including wetlands, however, 2 -year and 10 -year peak elevations shall be labeled for each of the stormwater ponds. (Appendix C.6.0.13.) 5. Lots abutting collector streets shall have an additional 10' of width or depth to be overlaid with a drainage & utility easement for a landscape bufferyard. (20-16-7-D) 6. Lot 72 through 82 Outlot I must encompass all of Pond IW. 7. Outlot 14 must be dedicated to City. 8. Legend must include wetland restoration, wetland, principal builder setbacks, wetland fill and wetland buffer. TRAFFIC/ACCESS ISSUE 1. Proposed intersection spacing along Randolph Ave. NE and within the development is appropriate. 2. Proposed access locations on CSAH 36 appear adequate pending approval of Wright County Highway Department considering the size of the development north and south of CSAH 36. An Intersection Control Evaluation (I.C.E.) may be requested by the County for the Randolph intersection. At a minimum, we would require expansion or pavement width of CSAH 36 to accommodate dedicated left hand turns. The addition of bypass waves at Road 7/CSAH6 intersection appears adequate. WETLANDS 1. Wetlands C, D, E, and F are proposed to be disturbed wetland. Avoidance of wetlands must be attempted. If wetlands must be disturbed or filled they must be mitigated as per WCA requirements. (20-16-9.E.2.) 2. A protective buffer of natural vegetation at least 20' wide from the delineated edge shall surround all wetlands. A principal building setback of 40' from the delineated edge of all wetlands or 20' from the protective buffer easement, whichever is greater, shall be provided (20-16-9.E.). Remove protective buffer, setback, and restoration from CSAH 36 right-of-way and wetland DW near the eastern plat boundary and wetland DW near the intersection of CSAH 36 and Road 1. We recommend renaming one of the wetlands DW to something unique. SURFACE WATER MANAGEMENT 1. The Normal, 2 yr, 10 yr, and 100 yr water elevation shall be depicted on the plans for each basin (Appendix C.6.013). The 10 yr calculations are missing from the stormwater report and plans. 2. A portion of the North Area discharges to the existing Riverplace Pond 3. We have reviewed the Stormwater report for Riverplace and this model do NOT account for the PAGE 5 SAM unicipal\Aotsego23xx\2328\ot2328RVW 1.doc runoff from this new development. Table 4.8 of the Lennar/Lahn property report indicates that the pond was remodeled to establish a new HWL elevation (which is lower than the original proposed HWL, 883.61 vs 884.0, based on new Atlas 14 rainfalls but we cannot find this model in the report. The Riverplace (RP) Pond 3 calculations shall be included to show that this additional drainage can be accommodated. (The attached shows a 61.2 acres "Pond 3 Subarea" from the RP report but the NURP Design for Pond 3 only indicates 26.1 acres flowing to it.) 2. Per City requirements, the post -development runoff rates for both the north and south areas are less than the pre -development rates though Table 4.3 and 4.4 discharge rates are lower that we would expect (for both pre and post conditions) due to the off-site discharges being routed through Links. 3. The hydraulic soils groups indicated are HSG Type C north of CSAH 36 and Type B south of CSAH 36, which agrees with the NRCS Soils report and soil boring for the site, therefore both areas require infiltration per the NPDES permit. The calculations supporting Table 4.5 "Summary of Infiltration Volumes" is required. The models do not indicate the infiltration ring in any of the ponds and no separate calculations can be found. 4. The report summarizes the dead storage volumes required for the North and South areas (per City requirements) in Table 4.2. Looking at the individual pond models for the 2.5" rain event it appears that some of these ponds have flow out during this event (and apparently not do to the infiltration ring below the NWL but through the weirs/outlet). The NURP volume requirements are for each storm water pond and cannot be averaged over the entire site. Wetlands do not provide/require dead storage as they are not to be used as treatment. Using them for rate control is acceptable. SANITARY SEWER COLLECTION SYSTEM 1. The trunk sanitary sewer along Randolph Avenue NE Trunk has sufficient depth and size to service the area north of the Lahn property and further north. No additional depth or pipe size is necessary with this development to service areas beyond the project boundary. WATER DISTRIBUTION SYSTEM 1. Midblock valve Road 1 between Road 4 and Road 3, and additional valves needed Road 1/Road 9, Road 10/Road 9, Road 13/Road 12. 2. Hydrant at end of lines for flushing and testing purposes end Road 12, Road 5, Road 7 and Road 3, intersection of Road I I/Road 5. 3. Hydrant Coverage appears adequate except in 4 areas, Lot 22, Lot 61, Lot 222, and Lot 281. PAGE 6 SAM unicipal\Aotsego23xx\2328\ot2328RVW 1.doc ENVIRONMENTAL 1. The Environmental Assessment Worksheet has been completed. It has been published in the EQB Monitor and Council has approved. OTHER CONSIDERATIONS 1. Benchmarks shall be shown on each sheet (see page 7 Section II1.14 of Engineering Manual). 2. Consideration is needed regarding who owns and will maintain the trails. SUMMARY AND/OR RECOMMENDATION We recommend approval contingent on the above comments being addressed. PAGE 7 SAM unicipal\Aotsego23xx\2328\ot2328RVW 1.doc